RENAULT SCENIC 2014 J95 / 3.G Petrol Injection - Sagem3000 Manual Online
Manufacturer: RENAULT, Model Year: 2014, Model line: SCENIC, Model: RENAULT SCENIC 2014 J95 / 3.GPages: 181
Page 81 of 181

PETROL INJECTION
Fault finding – Interpretation of faults17B
17B - 81V12 MR-372-J84-17B000$405.mif
SAGEM 3000
Program No.: A7
Vdiag No.: 44, 48PETROL INJECTION
Fault finding – Interpretation of faults
DF398
PRESENT
OR
STOREDFUEL CIRCUIT OPERATING FAULT
1.DEF : petrol circuit fault
NOTESPriority for dealing with a combination of faults:
Apply the procedure for dealing with faults DF081 Solenoid valve canister bleed and
DF085 Fuel pump relay first if they are present or stored.
Conditions for applying the fault finding procedure to stored faults:
The fault is declared present after an attempt is made to start the engine.
Special note:
–OBD warning light comes on.
Check the cleanliness, condition and fitting of the fuel vapour absorber.
Repair if necessary.
If the fault is still present, adjust the harness so that the fault status changes (present stored).
Look for any damage to the wiring harness, and check the condition and connection of the injection computer
and fuel vapour absorber connectors.
Repair if necessary.
If the fault is still present, check for the +12V on track 1 of the fuel vapour absorber.
If the +12V is not present, check the following connection for insulation, continuity and the absence of
interference resistance:
Fuel vapour absorber track 1 track 2 of connector PPM1 on the Protection and Switching Unit
Repair if necessary.
If the fault is still present, disconnect the battery and the injection computer.
Check the insulation, continuity and the absence of interference resistance on the following connection:
Computer, connectorC, track E1petrol vapour absorber track 2
Repair if necessary.
If the fault is still present, measure the resistance between tracks 1 and 2 of the fuel vapour absorber bleed
solenoid valve.
Replace the bleed solenoid valve for the fuel vapour absorber if the resistance is not 26 ±4 at 23 °C.
If the fault is still present, check the insulation, continuity and the absence of interference resistance on the
following connections:
Computer, connectorC, track D1 track 1 of the PEM connector of the Protection
and Switching Unit
Repair if necessary.
If the fault is still present, deal with the other faults, then proceed to the conformity check.
AFTER REPAIRFollow the instructions to confirm repair.
Deal with any other faults.
Clear the stored faults.
S3000_V44_DF398/S3000_V48_DF398JSAA741.0
MR-372-J84-17B000$405.mif
Page 82 of 181

PETROL INJECTION
Fault finding – Interpretation of faults17B
17B - 82V12 MR-372-J84-17B000$405.mif
SAGEM 3000
Program No.: A7
Vdiag No.: 44, 48
DF455
PRESENT
OR
STOREDLOW FUEL LEVEL SIGNAL
1.DEF : open circuit or short circuit
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present after an attempt is made to start the engine.
Run a multiplex network test (see 88B, Multiplex).
If the fault is still present, carry out fault finding on the Instrument panel system (see83A, Instrument panel).
AFTER REPAIRFollow the instructions to confirm repair.
Deal with any other faults.
Clear the stored faults.
JSAA741.0
Page 83 of 181

PETROL INJECTION
Fault finding – Interpretation of faults17B
17B - 83V12 MR-372-J84-17B000$405.mif
SAGEM 3000
Program No.: A7
Vdiag No.: 44, 48
DF608
PRESENT
OR
STOREDCLUTCH PEDAL SWITCH
1.DEF : signal incoherence
NOTESConditions for applying the fault finding procedure to stored faults:
The fault is declared present with the engine running and a road speed above 36 mph
(60 km/h).
Special note:
The acquisition is made if the vehicle is not fitted with an automatic transmission.
Check the cleanliness, condition and assembly of the clutch pedal switch and its connections.
Repair if necessary.
If the fault is still present, disconnect the switch. Check that when the clutch pedal is depressed, the switch is active,
and that when the clutch pedal is released, that the switch is not active and that the recommendations regarding
clutch pedal clearance are still valid (see MR 364, Mechanics,20A, Clutch
Replace the switch if necessary.
If the fault is still present, manipulate the harness so that the status changes (present stored).
Look for any damage to the wiring harness, and check the condition and connection of the injection computer
and clutch pedal switch connectors.
Repair if necessary.
If the fault is still present, check the earth on track 2 of the switch.
If there is no earth on track 2, check the insulation, continuity and the absence of interference resistance on
the following connection:
Clutch pedal switch track 2 earth
Repair if necessary.
If the fault is still present, check the insulation, continuity and the absence of interference resistance on the
following connections:
Clutch pedal switch track 1 Track C4, connector A, of the computer
Repair if necessary.
If the fault is still present, deal with the other faults, then proceed to the conformity check.
AFTER REPAIRFollow the instructions to confirm repair.
Deal with any other faults.
Clear the stored faults.
JSAA741.0
Page 84 of 181

PETROL INJECTION
Fault finding – Interpretation of faults17B
17B - 84V12 MR-372-J84-17B000$405.mif
SAGEM 3000
Program No.: A7
Vdiag No.: 44, 48
DF612
PRESENT
OR
STOREDOIL VAPOUR DEFREEZE RESISTOR CIRCUIT
CO.0 : open circuit or short circuit to earth
NOTESPriority for dealing with a combination of faults:
If the faults DF002 Air temperature sensor circuit, DF004 Turbocharging pressure
circuit, DF009 Gang 2 pedal potentiometer circuit or DF046 Battery voltage are
present, handle them first.
Conditions for applying the fault finding procedure to stored faults:
The fault appears after the ignition has been switched on.
Check the cleanliness and condition of the oil vapour defreeze resistor relay connections.
Clean or replace as necessary.
Measure the resistance of the defreeze resistor relay between tracks 1 and 2.
Replace the relay if the resistance is not:21at - 40 °C
9.5at 20 °C
13.4at 120 °C
With the ignition on, check for + 12 V on track 1 of the defreeze resistor relay.
Repair if necessary.
Disconnect the battery.
Disconnect the computer. Check the cleanliness and condition of the connections.
Using the Universal bornier, check the insulation, continuity and the absence of interference resistance for
the following connection:
Computer, connector B, track L2 track 2 of the oil vapour defreeze relay
Repair if necessary.
If the fault is still present, deal with the other faults, then proceed to the conformity check.
AFTER REPAIRFollow the instructions to confirm repair.
Deal with any other faults.
Clear the stored faults.
JSAA741.0
Page 85 of 181

PETROL INJECTION
Fault finding – Interpretation of faults17B
17B - 85V12 MR-372-J84-17B000$405.mif
SAGEM 3000
Program No.: A7
Vdiag No.: 44, 48
DF635
PRESENT
OR
STOREDLPG CYLINDER 1 COMBUSTION MISFIRE
1 DEF: Destructive misfire
2 DEF: Pollutant misfire
3 DEF: Non-compliance with emission control standards
NOTESPriority when dealing with a number of faults:
– LPG fuel system: see 17C, LPG injection,
– ignition:
DF072 Cylinder 1 ignition coil circuit
DF073 Cylinder 2 ignition coil circuit
DF074 Cylinder 3 ignition coil circuit
DF075 Cylinder 4 ignition coil circuit
– flywheel signal:
DF154 Flywheel signal sensor circuit
DF125 "Torque sensor programming"
Check whether there are other cylinders with an LPG combustion misfire fault detected
by the tool before starting the following fault finding procedure.
Conditions for applying the fault finding procedure to stored faults:
The fault appears under the following conditions:
– there must be no further electrical faults,
– the programming must have been done, particularly the flywheel target,
– warm engine (minimum 75 °C),
– run the engine at idle speed with all electrical consumers switched on for
approximately 15 minutes.
Special note:
– catalytic converter misfire: OBD warning light flashes when the fault is present then
is continuously lit,
– pollutant combustion misfire: OBD warning light lit continuously.
– engine unstable, loss of power and vibrations.
Misfiring on
cylinder 1 only
The fault is probably due to a component that can only affect this cylinder:
– check the cylinder 1 pencil coil,
– check the condition and conformity of the spark plugs,
– check the cylinder 1 LPG injector
If everything is in order, check the same components on cylinder 4 (to cover a possible
cylinder recognition error).
The fault is probably due to a component that affects a pair of cylinders:
– check the ignition coil circuit concerned (apply interpretation of fault
DF072 Cylinder 1 ignition coil circuit
DF073 Cylinder 2 ignition coil circuit
DF074 Cylinder 3 ignition coil circuit
DF075 Cylinder 4 ignition coil circuit
– check the condition and conformity of the spark plugs.
Combustion
misfires on
cylinders 1 and 4
AFTER REPAIRFollow the instructions to confirm repair.
Deal with any other faults.
Clear the stored faults.
Page 86 of 181

PETROL INJECTION
Fault finding – Interpretation of faults17B
17B - 86V12 MR-372-J84-17B000$405.mif
SAGEM 3000
Program No.: A7
Vdiag No.: 44, 48
DF636
PRESENT
OR
STOREDLPG CYLINDER 2 COMBUSTION MISFIRE
1 DEF: Destructive misfire
2 DEF: Pollutant misfire
3 DEF: Non-compliance with emission control standards
NOTESPriority when dealing with a number of faults:
– LPG fuel system: see 17C, LPG injection,
– ignition:
DF072 Cylinder 1 ignition coil circuit
DF073 Cylinder 2 ignition coil circuit
DF074 Cylinder 3 ignition coil circuit
DF075 Cylinder 4 ignition coil circuit
– flywheel signal:
DF154 Flywheel signal sensor circuit
DF125 "Torque sensor programming"
Check whether there are other cylinders with an LPG combustion misfire fault detected
by the tool before starting the following fault finding procedure.
Conditions for applying the fault finding procedure to stored faults:
The fault appears under the following conditions:
– there must be no further electrical faults,
– the programming must have been done, particularly the flywheel target,
– warm engine (minimum 75 °C),
– run the engine at idle speed with all electrical consumers switched on for
approximately 15 minutes.
Special note:
– catalytic converter misfire: OBD warning light flashes when the fault is present then
is continuously lit,
– pollutant combustion misfire: OBD warning light lit continuously.
– engine unstable, loss of power and vibrations.
Misfiring on
cylinder 2 only
The fault is probably due to a component that can only affect this cylinder:
– check the cylinder 2 pencil coil,
– check the condition and conformity of the spark plugs,
– check the cylinder 2 LPG injector
If everything is in order, check the same components on cylinder 3 (to cover a possible
cylinder recognition error).
The fault is probably due to a component that affects a pair of cylinders:
– check the ignition coil circuit concerned (apply interpretation of fault
DF072 Cylinder 1 ignition coil circuit
DF073 Cylinder 2 ignition coil circuit
DF074 Cylinder 3 ignition coil circuit
DF075 Cylinder 4 ignition coil circuit
– check the condition and conformity of the spark plugs.
Combustion
misfires in
cylinders 2 and 3
AFTER REPAIRFollow the instructions to confirm repair.
Deal with any other faults.
Clear the stored faults.
Page 87 of 181

PETROL INJECTION
Fault finding – Interpretation of faults17B
17B - 87V12 MR-372-J84-17B000$405.mif
SAGEM 3000
Program No.: A7
Vdiag No.: 44, 48
DF637
PRESENT
OR
STOREDLPG CYLINDER 3 COMBUSTION MISFIRE
1 DEF: Destructive misfire
2 DEF: Pollutant misfire
3 DEF: Non-compliance with emission control standards
NOTESPriority when dealing with a number of faults:
– LPG fuel system: see 17C, LPG injection,
– ignition:
DF072 Cylinder 1 ignition coil circuit
DF073 Cylinder 2 ignition coil circuit
DF074 Cylinder 3 ignition coil circuit
DF075 Cylinder 4 ignition coil circuit
– flywheel signal:
DF154 Flywheel signal sensor circuit
DF125 "Torque sensor programming"
Check whether there are other cylinders with an LPG combustion misfire fault detected
by the tool before starting the following fault finding procedure.
Conditions for applying the fault finding procedure to stored faults:
The fault appears under the following conditions:
– there must be no further electrical faults,
– the programming must have been done, particularly the flywheel target,
– warm engine (minimum 75 °C),
– run the engine at idle speed with all electrical consumers switched on for
approximately 15 minutes.
Special note:
– catalytic converter misfire: OBD warning light flashes when the fault is present then
is continuously lit,
– pollutant combustion misfire: OBD warning light lit continuously.
– engine unstable, loss of power and vibrations.
Misfiring on
cylinder 3 only
The fault is probably due to a component that can only affect this cylinder:
check the cylinder 3 pencil coil,
check the condition and conformity of the spark plugs,
check the cylinder 3 LPG injector
If everything is in order, check the same components on cylinder 2 (to cover a possible
cylinder recognition error).
The fault is probably due to a component that affects a pair of cylinders:
– check the ignition coil circuit concerned (apply interpretation of fault
DF072 Cylinder 1 ignition coil circuit
DF073 Cylinder 2 ignition coil circuit
DF074 Cylinder 3 ignition coil circuit
DF075 Cylinder 4 ignition coil circuit
– check the condition and conformity of the spark plugs.
Combustion
misfires in
cylinders 2 and 3
AFTER REPAIRFollow the instructions to confirm repair.
Deal with any other faults.
Clear the stored faults.
Page 88 of 181

PETROL INJECTION
Fault finding – Interpretation of faults17B
17B - 88V12 MR-372-J84-17B000$405.mif
SAGEM 3000
Program No.: A7
Vdiag No.: 44, 48
DF638
PRESENT
OR
STOREDLPG CYLINDER 4 COMBUSTION MISFIRE
1 DEF: Destructive misfire
2 DEF: Pollutant misfire
3 DEF: Non-compliance with emission control standards
NOTESPriority when dealing with a number of faults:
– LPG fuel system: see 17C, LPG injection,
– ignition:
DF072 Cylinder 1 ignition coil circuit
DF073 Cylinder 2 ignition coil circuit
DF074 Cylinder 3 ignition coil circuit
DF075 Cylinder 4 ignition coil circuit
– flywheel signal:
DF154 Flywheel signal sensor circuit
DF125 "Torque sensor programming"
Check whether there are other cylinders with an LPG combustion misfire fault detected
by the tool before starting the following fault finding procedure.
Conditions for applying the fault finding procedure to stored faults:
The fault appears under the following conditions:
– there must be no further electrical faults,
– the programming must have been done, particularly the flywheel target,
– warm engine (minimum 75 °C),
– run the engine at idle speed with all electrical consumers switched on for
approximately 15 minutes.
Special note:
– catalytic converter misfire: OBD warning light flashes when the fault is present then
is continuously lit,
– pollutant combustion misfire: OBD warning light lit continuously.
– engine unstable, loss of power and vibrations.
Misfiring on
cylinder 4 only
The fault is probably due to a component that can only affect this cylinder:
– check the pencil coil of cylinder 4,
– check the condition and conformity of the spark plugs,
– check the cylinder 4 LPG injector
If everything is in order, check the same components on cylinder 1 (to cover a possible
cylinder recognition error).
The fault is probably due to a component that affects a pair of cylinders:
– check the ignition coil circuit concerned (apply interpretation of fault
DF072 Cylinder 1 ignition coil circuit
DF073 Cylinder 2 ignition coil circuit
DF074 Cylinder 3 ignition coil circuit
DF075 Cylinder 4 ignition coil circuit
– check the condition and conformity of the spark plugs.
Combustion
misfires on
cylinders 1 and 4
AFTER REPAIRFollow the instructions to confirm repair.
Deal with any other faults.
Clear the stored faults.
Page 89 of 181

PETROL INJECTION
Fault finding – Interpretation of faults17B
17B - 89V12 MR-372-J84-17B000$405.mif
SAGEM 3000
Program No.: A7
Vdiag No.: 44, 48
DF639
PRESENT
OR
STOREDCOMBUSTION MISFIRE IN LPG MODE
1 DEF: Destructive misfire
2 DEF: Pollutant misfire
3 DEF: Non-compliance with emission control standards
NOTESPriority when dealing with a number of faults:
– LPG fuel system: see 17C, LPG injection,
– ignition:
DF072 Cylinder 1 ignition coil circuit
DF073 Cylinder 2 ignition coil circuit
DF074 Cylinder 3 ignition coil circuit
DF075 Cylinder 4 ignition coil circuit
– flywheel signal:
DF154 Flywheel signal sensor circuit
DF125 "Torque sensor programming"
DF059 Combustion misfire in cylinder 1,
DF060 Combustion misfire in cylinder 2,
DF061 Combustion misfire in cylinder 3,
DF062 Combustion misfire in cylinder 4.
Conditions for applying the fault finding procedure to stored faults:
The fault appears under the following conditions:
– there must be no further electrical faults,
– the programming must have been done, particularly the flywheel target,
– warm engine (minimum 75 °C),
– run the engine at idle speed with all electrical consumers switched on for approximately
15 minutes.
Special note:
– catalytic converter misfire: OBD warning light flashes when the fault is present then is
continuously lit,
– pollutant combustion misfire: OBD warning light lit continuously.
– engine unstable, loss of power and vibrations.
Check the LPG injectors.
Check the condition and conformity of the spark plugs.
Check the ignition pencil coils.
If the fault is still present, carry out the following checks:
– check the flywheel sensor,
– check the condition and cleanliness of the flywheel,
– check the flywheel sensor mounting
– check the sensor/flywheel air gap,
– check the cylinder compression's,
– check the LPG fuel system,
– check the complete ignition system (see MR 364 or 370 Mechanics, 17A, Ignition),
– check the hydraulic tappets if there is camshaft noise (see MR 364 or 370 Mechanics, 11A, Top and front of engine).
If the fault is still present, deal with the other faults, then proceed to the conformity check.
AFTER REPAIRFollow the instructions to confirm repair.
Deal with any other faults.
Clear the stored faults.
Page 90 of 181

PETROL INJECTION
Fault finding – Conformity check17B
17B-90V12 MR-372-J84-17B000$450.mif
SAGEM 3000
Program No.: A7
Vdiag No.: 44, 48PETROL INJECTION
Fault finding – Conformity check
MAIN COMPUTER STATUSES AND PARAMETERS
NOTESOnly check conformity after a thorough check with the diagnostic tool.
The values shown in this conformity check are given as a guide. Application
condition: engine off, ignition on.
Order FunctionParameter or Status
Checked or ActionDisplay and notes Fault finding
1
Battery
voltagePR071: Computer
feed voltage11V
interpretation of PR071
Computer supply
voltage. 2 ET001: Computer +
after ignition
feedPresence of + After
ignition feed
Absent
3Water
pumpET543: Coolant
pump controlFor F4R Turbo engine only.
ACTIVE: coolant pump
running
INACTIVE: coolant pump idle.In the event of a fault, apply
interpretation of DF086
Coolant pump relay
control circuit.
4Vehicle
speedPR089: Vehicle
speedGives the vehicle speed in
mph (km/h). This parameter
is sent to the injection by
the ABS computer via the
multiplex network.If there is a fault use the
interpretation for DF091
Vehicle speed signal.
5Clutch
contactET040: Clutch pedalIndicates recognition of
clutch pedal contacts.
RELEASED: Pedal released
DEPRESSED: Pedal
depressed
UNAVAILABLE: Automatic
transmission onlyIn the event of a fault, use
the interpretation of ET040
Clutch pedal.
S3000_V44_CCONF/S3000_V48_CCONFJSAA741.0
MR-372-J84-17B000$450.mif