light DACIA SUPERNOVA 2004 Workshop Manual
Page 480 of 933
82A
HORN - ENGINE IMMOBILISER
82A - 13
NOTE
For the RF remote control synchronisation, after the replacement of an E.C.U.
decoder, the synchronisation procedure must be performed taking into account the
following situations: -for one RF re m ot e c ont ro l , pe rf orm t he “ SIMP L E SY NC H RONIS ED
PRO CEDURE”;
-f or the second RF remote control perform the “SPECIFIC SYNCHRONISED
PRO CEDURE”.
B. KIT REPLACEMENT PROCEDURE(E.C.U. decoder plus 2 key he ads)
In case of one kit replacement perform the following steps:
- memorising the anti starting code by the E.C.U. decoder
- memorising of the new anti starting code by the injection computer; i t is necessary the
repairing code (found out based on the old ke y heads code) and t he CLIP tester.
Perform the actions in the following sequence:
1. Mount the metal insertions of the old keys to the new key heads.
2. Send to Tech Line the key heads code, written on the vehicle invoice, in order to get the
repairing code. 3. Connect the CLIP tester to the diagnostic socket and to the battery (or t o the lighter
socket) of the vehicle. Read the configuration of the old E.C.U. decoder before dismounting off
the vehicle, as follows: - select vehicle type “SUPERNOVA” and the “050” equipping level;
- enter the menu “ COMPUTER TEST” then choose “ ANTI STARTING”;
- access “COMMAND MODE” then “READ CONFIGURATIONS”;
- note the configurations : petrol/diesel, programming with 1 or 2 keys, ceiling delay, the
type of the doors’ blocking switch (CPE), etc.;
4. Get back to the m enu “ANTI STARTING”;
5. Dismount the old E.C.U. decoder and replace it with a new one, the contact being off.
6. Check the configuration of the new E.C.U. decoder selecting “ STATE LIST”; here you
must find the following states: 18G FIRST CYCLE MEMORISINGPASSIVE…………………INACTIVE
19G NOT PERFORMED KEY PROGRAMMING ……………….ACTIVE
19D UNLOCKED KEY PROGRAMMING ………………………ACTIVE
NOTE
If the state 19G and 19D are not “ACTIVE” this m eans the E.C.U. decoder isn’t a
n ew one and cannot memorise another anti starting c ode. PROCEDURES
vnx.su
Page 481 of 933
82A
HORN - ENGINE IMMOBILISER
82A - 14
7. Set the contact in “M” position with one of the keys (without starting the engine), for about
2 seconds and then check the following states, which must be:
9D RECEIVED KEY CODE………………………………………. ACTIVE
19G NOT PERFORMED KEY PROGRAMMING ……………… ACTIVE
8. Set the contact with the second key (without starting the engine) for about 2 seconds.
Check then the following states:
-case (a)- the second key belongs to the vehicle;9D RECEIVED KEY CODE………………………………………. ACTIVE
19G NOT PERFORMED KEY PROGRAMMING……………… PASSIVE
- case (b)- the second key does not belong to the vehicle or the first key was used once again;
9D RECEIVED KEY CODE………………………………………PASSIVE
19G NOT PERFORMED KEY PROGRAMMING……………… ACTIVE
9. The anti starting indicator blinks rapidly.
10. Take off the contact. In t he menu “COMMAND MODE” select “ACTUATORS” and
validate “ FINISHED CALIBRATION” launching the command on the blue rectangle situated
on the right top of the screen. The message “COMMAND IN PROGRESS” will appear,
followed by “ FINISHED COMMAND”. 11 . The anti starting indicator will blink rarely.
12. Get back to the “ STAT E LIST”, which now must be as follows: 18G FIRST CYCLE MEMORISING……………………………... ACTIVE
19G NOT PERFORMED KEY PROGRAMMING……………… PASSIVE
19D UNLOCKED KEY PROGRAMMING………………………PASSIVE
13. In the m enu “COMMAND MODE” choose “ ACTUATORS”. Select the command “
FORCED PROTECTION MODE” launching the command from the blue button situated on
the ri ght topside of the screen. The display will show “COMMAND IN PROGRESS” and
then “FINISHED COMMAND”. Get back to t he “STATE LIST “ and check the state:
9G FORCED PROTECTION MODE …………………………….. ACTIVE
14. Set the contact on “M” position. The anti starting indicator will start to blink rapidly. Check
in the “ STATE LIST” if the state “ANTI STARTING” is “ACTIVE”.
15. In the menu “COMMAND MODE” access “ACTUA TORS”, then select the command “
MANUAL INTRODUCTI ON CODE”. Type the four figures of the repairing code, then validate
with the key “ENTER”. On the screen the message “COMMAND IN PROGRESS” will
appear and then “FINISHED COMMAND”. 16. Take off and then set again the contact, without starting the engine, in order to send the
new anti starting code to the injection computer. The anti starting indicator will light for 3 seconds,
and then it will turn off.
17. The procedure is finished. Check the engine starting with both keys. PROCEDURES
vnx.su
Page 482 of 933
82A
HORN - ENGINE IMMOBILISER
82A - 15
NOTE
For the RF remote control synchronisation, after the replacement of a kit, take into
account the fol lowing situations: - for the first RF remote control, perform the “ simple synchronised procedure”;
- for the second RF remote c ontrol perform the “specific synchronised procedure” .
C. CODE REPAIRING INTRODUCTION PROCEDURE
The repairing code may be introduced only by the means of the CLIP tester. This is possible
only if when setting the contact on, the anti starting indicator blinks rapidly, this being confirmed
by the state: 10G ANTI STARTING…………………………………………….. ACTIVE
After getting from DACIA database the repairing code (based on the code from the vehicle’s
key head), perform the following operations. 1. Connect the CLIP tester to the diagnostic socket and to the battery (or to the lighter
socket) of the vehicle. 2. The anti start up indicator must blink slowly , the contact being taken off.
3. Set the contact in “M” position. The indicator must blink rapidly.
4. Select vehicle type “SUPERNOVA” and “050” equipping level.
5. Select the menu “ COMPUTER TEST” then choose “ ANTI STARTING”.
6. In the menu “ STAT E L IST” find t he state 10G “ANTI STARTING” which m ust be
“ACTIVE”.
7. Access “COMMAND MODE” then select “ACTUATORS”.
8. Select the command “ MANUAL INTRODUCTION CODE” where you will write the
repairing code (formed of four figures), then validate it with the key “ENTER”. T he message
“COMMAND IN PROGRESS” will be displayed followed by the message “FINISHED
COMMAND”.
9. Now the procedure is finished and you may start the vehicle engine.
AT TENT ION
You may perform three essays of introducing the repairing code; if aft er the third
essay the code is not yet valid, wait for 15 minutes, take off the contact and then put it
again, other t hree essays being allowed.
NOTE
This procedure does not decode the injection computer, but allows only the start of
the vehicle’s engine. After ten minutes have passed from the first introduction of the
r epairing code or after the disconnection of the battery, the vehicle’s engine cannot be
s tarted unless a new repairing code is introduced. PROCEDURES
vnx.su
Page 483 of 933
82A
HORN - ENGINE IMMOBILISER
82A - 16
D. SIMPLE S
YNCHRONISED PROCEDURE
This procedure allows the synchronisation of a RF remote control with E.C.U. decoder and
is to be applied in the following situations:
- the RF remote control c ode is no longer i n the range of the E.C.U. decoder re ception,
because of consecutive pushing over a 1000 time on the RF remote control button.;
- the replacement of the E.C.U. decoder with a new one;
- the replacement of the RF remote control if the E.C.U. decoder is new (E.C.U. decoder
replacement plus a RF key.)
The following operations will be performed: - take off t he contact
- push and maintain like that for about 5 seconds, the doors locking switch located on the
dashboard ; the doors actuators are performing a closing/opening course.
- during the next 10 seconds, confirmed by the permanent lightening of the anti starting
system indicator, push twice the RF remote control button; the doors actuators are performing a
closing/o pening course.
- the procedure of synchronisation is finished; check the blocking/ unlocking by pushing
the RF remote control.
OBSERVAT ION
Duri ng those 10 seconds you can visualise by means of the CLIP tester the state 17G
“THE PROGRAMMING IN PROGRESS OR THE TIR/TRF
RESYNCHRONISATION” which must be ACTIVE.
E. SPECIFIC SYNCHRONISED PROCEDURE
This procedure is used for the synchronisation of the second RF key with E .C.U. decoder
and will be performed as follows:
- connect the CLIP tester to the diagnostic socket and the battery (or the lighter socket) of
the vehicle. - select the vehicle type “SUPERNOVA” and the “050” equipping level;
- select the m enu “ COMPUTERS TEST” then “ ANTI STARTING”
- enter the m enu “COMMAND MODE” and select “CONFIGURATION”
- validate the command “ PROGRAMMI NG THE SECOND TIR / TRF KEY” launching
the command from the blue button situated on the right top of the screen; the doors actuators are
performing a closing/opening course.
- during the next 10 seconds, confirmed by the permanent lightening of the anti starting
system, push twice the RF remote control button; the doors will block and then unlock and the
anti starting indicator will t urn off. The second remote control is now synchronised. Check the
blocking/ unlocking by pushing the RF remote control. PROCEDURES
vnx.su
Page 487 of 933
82A
HORN - ENGINE IMMOBILISER
82A - 20
D)
Memorising of the new code of the injection computer
- in ACTUATORS
launch the command MANUAL INTRODUCTION CODE ; type
the repairing code of the old key kit, then validate it with the key
ENTER.
- the message “COMMAND IN PROGRESS ” will be displayed followed by the message
“FINISHED COMMAND ”.
-s et the contact on; t he anti starting LED indicator will start blinking, then take off the
contact;
-set the c ontact on for 10 seconds ; take off the contact;
- check if the engine starts with the two keys.
If the engine doesn’t start, repeat this operation (point D).
E) Key resynchronisation (remote controls)
-if the vehicle is equipped with only one remote control, its resynchronisation will be
performed as follows (simple resynchronisation);
- with t he contact taken off, push continuously on the c entra l l ocking but ton from the
dashboard, up to the moment the anti starting LED indicator remains lighted (the doors actuators
are performing a closing/opening course.) From this moment, t he operator has 10 seconds to
perform the next operation; - push twice on the remote control (the doors actuators are performing a closing/opening
course.) and the anti starting LED indicator turns off; - if the vehicle is equipped with two remotes controls, perform the simple resynchronisatio n
procedure for the first key and a specific resynchronisation procedure for the second key, with
the CLIP tester as follows: - in COMPUTER TEST select ANTISTARTING with t he c ontact t aken off, then
COMMAND MODE , CONFIGURATION ; launch the command PROGRAMMING OF
THE SECOND TIR/TIE KEY and validate (the doors actuators are performing a closing/
opening course.). Then within 10 seconds, push twice on the remote control (the doors actuators
are performing a closing/o pening course).DIAGNOSTIC
vnx.su
Page 499 of 933
82A
HORN - ENGINE IMMOBILISER
82A - 32
ALP3. THE ANTI STARTING INDICATOR REMAINS PERMANENTLY LIGHTED
(even when the contact is taken off) OR IT REMAINS PERMANENTLY SWITCHE D OFF.
RECOMMENDATIONCheck if the “Procedure E.C.U. decoder replacement” was correctly
performed.
Check the fuse F15 ( up to 01.06.2001) or
F07 (after 01.06.2001).
Is the fuse good?
Is there the failure “ DOORS’ LOCKING
CONTACT”?
Check the continuity and the isolation related
to the ground, between t he pin A 5 of the
E.C.U. decoder and the dashboard.
Is the wiring good?
Replace the fuse.
Analyse this failure and replace.
Fix the wiring.
Perform the following tests in order to find the
failure element:
- if the anti starting indicator is permanently
lighted, disconnect the connector of the E.C.U.
decoder and check if the indicator switches off;
- if the anti starting system is turned off,
c onnect the pin A5 of the wiring connector from
the E.C.U. decoder to an electric ground and
check if the indicator turns on.
Are the answers affirmatives?
Replace the instrument panel.
Replace the E .C.U. decoder.
Perform a conformity checking.
AFTER REPAIRING Check the operation of the anti starting system. Remove by means of the CLIP tester the possibl e memorised failures.
No
No
No
Yes
Yes
No
Yes
YesDIAGNOSTIC
vnx.su
Page 504 of 933
82A
HORN - ENGINE IMMOBILISER
82A - 37
A
LP8. TURNING LIGHTS DO NOT SWITCH ON AT THE BLOCKING /
UNLOCKING OF THE DOORS
RECOMMENDATION Check the absence of the failures with the CLIP tester.
If there are failures, fix them first.
Check if the synchronisatio n of the RF remote control and the E.C.U. decoder has been performed .
Are the turning lights functioning normally at the activation of the signalling switch ?
Check the continuity and the isolation related to
the ground and the +12 V of the electric layout:
E.C.U. decoder FLASH relay
Pin B3 pole 2
Is it correct?
Repair the signalli ng system.
Check t he fuse F03 and F04.
Fix the electric layout.
Check the fuse F15 ( up to 01.06.2001) or
F 07 (after 01.06.2001).
Is it good?Replace the fuse.
Disconnect the FLASH relay. Supply with
+ 12, the pole 4 of the relay. Are the l eft
turning lights turning on? Supply with +12 V
the pole 5 of the signal relay.
Are the right turning lights turning on?
Repair the electric layout from
poles 4 and 5 of the FLASH relay.
Replace the FLASH relay.
AFTER REPAIRING Perform a conformity checking.
Check the operation of the anti starting system.
No
No
No
Yes
Yes
Yes
Yes No
DIAGNOSTIC
vnx.su
Page 505 of 933
82A
HORN - ENGINE IMMOBILISER
82A - 38
No
AFTER REPAIRING Perform a conformity
checking.
Check the operation of the anti starting system.
A LP9. THE CEILING LAMP DOES NOT SWITCH ON AT THE BLO CKING /
UNLOCKING OF THE DOORS OR IT REMAINS PERMANENTLY TURNED ON.
RECOMMENDATION Check the absence of failures with the CLIP tester.
If there are memorised failures, fix them first.
Check if t he doors are locked?
Has the ceiling lamp turned on? The ceiling lamp was in the
position “p
ermanently
lighting”. Normal
operation.Yes Yes
Unlock the doors with the RF remote control.
The ceiling is in the position “dome lighting”
Has the ceiling lamp turned on?
Check the isolation of the wiring
related to the ground on the line pinA1.
decoder ceiling
After 15 seconds, the ceiling lamp will
turn off.
Normal operation.
Was the E.C.U. decoder confi gured “With
dome ceiling ”?Configure the E.C.U. decoder with
the CLIP tester.
Check the continuity on the line
E. C.U. decoder pin A1 ceiling
Is the line good?Repair .
Check the ceiling lamp bulb.
No
No
No
Yes
Yes Yes
No
DIAGNOSTIC
vnx.su
Page 508 of 933
82B
HORN - ENGINE IMMOBILISER
82B - 41
GENERALITIES
DESCRIPTION
The a nti intrusion system has t he purpose of peripheral prot ection of the ve hicle a nd the
volumetric protecti on of the passengers compartment (cockpit) and has the following components:
The ECU anti intrusion (1) is located under the central console, being attached under the
climate control unit and receives information from the volumetric sensors and from the contacts
of: front doors, engine hood and tail hatchback.
In case of an intrusion into the vehicle, when the system is activated, ECU will start t he siren
combined with intermittent lightening of the turning lamps.
The volumetric sensors (2) are fixed on the upholstery of the left and right upper part of the
pillars. After the activation of the anti intrusion system with the remote control, the sensors c an
supply information to the ECU concerning the interior volume of the cockpit, which, in case of its
modification will produce the siren starting and the intermittent lightening of the turning lamps.
The siren (3) is fixed on a frame, being located in the climate control unit and it is controlled by
the ECU anti intrusion.
The intrusion LED indicator (4) is located on the dashboard, on the left side and it indicates if
the system is activated or not and in case of an aggression on the vehicle, the indicator will show
the type of aggression.
The contacts of the front and rear doors (5), of the e ngine hood (6) a nd of the hatchback (7)
are supplying information concerning their opening, to the ECU anti intrusion, when the system is
activated.
1 3
6
4
7
5
2
vnx.su
Page 509 of 933
82B
HORN - ENGINE IMMOBILISER
82B - 42
The anti intrusio
n system may be activated or deactivated by pushing the button of the RF remote
control of the vehicle key and it is achieving the peripheral protection of the vehicle and the volumetric
protectio n of the cockpit. The activation of the system is indicated on the instru ment panel by the LED
indicator, which will start to blink, and is confirmed by two blinks of the turning lights. Deactivation is
confirmed by a blink of the turning lights and LED indicator switching off.
In case of the vehicles equipped with central locking system, the doors will lock when the system
is activated and will unlock when deactivating the anti intrusion system. After 40 seconds from
remote control activatio n, the opening of a door, of the hood or the hatchback will cause the siren
starting and turning lights blinking for 30 seconds; after 30 seconds, the system remains activated.
During those 40 seconds, the volumetric sensors will “read” the volume of the cockpit, this
“reading” being reinitialised on every activation of the system, in order to take into account the
potential volume modifications. Any modifications of the inner volume of the cockpit ( broken
w indow glass, intrusion in the cockpit or movement inside the cockpit) will perturb the ultra-
sound emission field causing the siren starting.
The system does not normally operate unless all doors, the engine hood, the hatchback and
the window glasses are properly closed. If one of the front doors, the engine hood or the hatchback
is not well c losed, at the doors locking with the RF remote c ontrol, the t urning lights will not
switch on at all. At the deactivation with RF remote control, the traffic indicators will switch on,
just once.
AT TENT ION
In case of one door opening by key, while the anti intrusion system is
activated, the siren will start and it can be stopped by pressing the remote button or by
introducing the PIN code which is written on the vehicle invoice.
SY STEM FUNCTIONNING
vnx.su