diagram INFINITI QX4 2001 Factory Service Manual

Page 1466 of 2395

DOOR SWITCH CHECK=NBEL0115S05
1 CHECK DOOR SWITCH INPUT SIGNAL
Check voltage between smart entrance control unit terminals 28, 29 or 40 and ground.
SEL305X
Refer to wiring diagram in EL-275.
OK or NG
OK©Door switch is OK.
NG©GO TO 2.
2 CHECK DOOR SWITCH
1. Disconnect door switch connector.
2. Check continuity between door switch terminals.
SEL306X
OK or NG
OK©Check the following.
IDoor switch ground circuit (Front, back door) or door switch ground condition
IHarness for open or short between smart entrance control unit and door switch
NG©Replace door switch.
GI
MA
EM
LC
EC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
IDX
MULTI-REMOTE CONTROL SYSTEM
Trouble Diagnoses (Cont'd)
EL-281

Page 1467 of 2395

KEY SWITCH (INSERT) CHECK=NBEL0115S07
1 CHECK KEY SWITCH INPUT SIGNAL
Check voltage between smart entrance control unit terminal 32 and ground.
SEL307X
Refer to wiring diagram in EL-274.
OK or NG
OK©Key switch is OK.
NG©GO TO 2.
2 CHECK KEY SWITCH (INSERT)
Check continuity between terminals 1 and 2.
SEL308X
OK or NG
OK©Check the following.
I7.5A fuse [No. 24, located in fuse block (J/B)]
IHarness for open or short between key switch and fuse
IHarness for open or short between smart entrance control unit and key switch
NG©Replace key switch.
MULTI-REMOTE CONTROL SYSTEM
Trouble Diagnoses (Cont'd)
EL-282

Page 1468 of 2395

DOOR LOCK/UNLOCK SWITCH LH CHECK=NBEL0115S10
1 CHECK DOOR LOCK/UNLOCK SWITCH INPUT SIGNAL
1. Disconnect smart entrance control unit connector.
2. Check continuity between control unit terminal 23 or 35 and ground.
SEL309X
Refer to wiring diagram in EL-274.
OK or NG
OK©Door lock/unlock switch is OK.
NG©GO TO 2.
2 CHECK DOOR LOCK/UNLOCK SWITCH
1. Disconnect door lock/unlock switch connector.
2. Check continuity between each door lock/unlock switch terminals.
IPower window main switch (Door lock/unlock switch LH)
SEL310X
OK or NG
OK©Check the following.
IGround circuit for door lock/unlock switch
IHarness for open or short between door lock/unlock switch and smart entrance control
unit connector
NG©Replace door lock/unlock switch.
GI
MA
EM
LC
EC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
IDX
MULTI-REMOTE CONTROL SYSTEM
Trouble Diagnoses (Cont'd)
EL-283

Page 1469 of 2395

FRONT LH DOOR UNLOCK SENSOR CHECK=NBEL0115S06
1 CHECK FRONT LH DOOR UNLOCK SENSOR INPUT SIGNAL
Check voltage between smart entrance control unit terminal 36 and ground.
SEL323X
Refer to wiring diagram in EL-275.
OK or NG
OK©Door unlock sensor is OK.
NG©GO TO 2.
2 CHECK FRONT LH DOOR UNLOCK SENSOR
1. Disconnect front LH door unlock sensor connector.
2. Check continuity between door unlock sensor terminals.
SEL324X
OK or NG
OK©Check the following.
IDoor unlock sensor ground circuit
IHarness for open or short between smart entrance control unit and door unlock sensor
NG©Replace door unlock sensor.
MULTI-REMOTE CONTROL SYSTEM
Trouble Diagnoses (Cont'd)
EL-284

Page 1470 of 2395

HAZARD REMINDER CHECK=NBEL0115S08
1 CHECK HAZARD INDICATOR
Check if hazard indicator flashes with hazard switch.
Does hazard indicator operate?
Ye s©GO TO 2.
No©Check ªhazard indicatorº circuit.
2 CHECK HAZARD REMINDER OPERATION
1. Disconnect smart entrance control unit connector.
2. Apply ground to control unit terminal 7.
SEL325X
Refer to wiring diagram in EL-276.
OK or NG
OK©Replace smart entrance control unit.
NG©GO TO 3.
3 CHECK MULTI-REMOTE CONTROL RELAY
Check multi-remote control relay.
OK or NG
OK©GO TO 4.
NG©Replace.
GI
MA
EM
LC
EC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
IDX
MULTI-REMOTE CONTROL SYSTEM
Trouble Diagnoses (Cont'd)
EL-285

Page 1472 of 2395

HORN REMINDER CHECK=NBEL0115S11
1 CHECK HORN
Check if horn sounds with horn switch.
Does horn operate?
Ye s©GO TO 2.
No©Check horn circuit.
2 CHECK HORN REMINDER OPERATION
1. Disconnect smart entrance control unit connector.
2. Apply ground to smart entrance control unit terminal 19.
SEL328X
Refer to wiring diagram in EL-276.
OK or NG
OK©Replace smart entrance control unit.
NG©Check harness for open or short between smart entrance control unit and horn relay.
GI
MA
EM
LC
EC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
IDX
MULTI-REMOTE CONTROL SYSTEM
Trouble Diagnoses (Cont'd)
EL-287

Page 1473 of 2395

INTERIOR ROOM LAMP OPERATION CHECK=NBEL0115S09
1 CHECK INTERIOR ROOM LAMP
Check if the interior room lamp switch is in the ªONº position and the lamp illuminates.
Does interior room lamp illuminate?
Ye s©GO TO 2.
No©Check the following.
IHarness for open or short between smart entrance control unit and interior room lamp
IInterior room lamp
2 CHECK INTERIOR ROOM LAMP CIRCUIT
When interior room lamp switch is ªDOORº position, check voltage across smart entrance control unit terminal 8 and
ground.
SEL329X
Refer to wiring diagram in EL-274.
OK or NG
OK©GO TO 3.
NG©Repair harness between smart entrance control unit and interior room lamp.
3 CHECK CONTROL UNIT OUTPUT
Push unlock button of remote controller with key removed and all doors closed, and check voltage across smart entrance
control unit terminal 8 and ground.
SEL330X
OK or NG
OK©Check system again.
NG©Replace smart entrance control unit.
MULTI-REMOTE CONTROL SYSTEM
Trouble Diagnoses (Cont'd)
EL-288

Page 1485 of 2395

Wiring Diagram Ð THEFT ÐNBEL0122FIG. 1NBEL0122S01
MEL009O
THEFT WARNING SYSTEM
Wiring Diagram Ð THEFT Ð
EL-300

Page 1486 of 2395

FIG. 2NBEL0122S02
MEL859L
GI
MA
EM
LC
EC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
IDX
THEFT WARNING SYSTEM
Wiring Diagram Ð THEFT Ð (Cont'd)
EL-301

Page 1487 of 2395

FIG. 3NBEL0122S03
MEL860L
THEFT WARNING SYSTEM
Wiring Diagram Ð THEFT Ð (Cont'd)
EL-302