NISSAN ALMERA N15 1995 Service Manual

Page 1061 of 1701


~i5

cf0
TROUBLE
DIAGNOSIS FORNON-DETECTABLE ITEMS
Idle AirControl Valve(IACV)-FICD Solenoid
Valve (Cont'd)

@

AEC766 CHECK
GROUND CIRCUIT.

1. Turn ignition switch"OFF".
2. Check harness continuity between
terminal
@
and body ground.

Continuity shouldexist.

If OK, check harness forshort.

OK

CHECK COMPONENT
(IACV-FICD solenoidvalve).
Refer to"COMPONENT INSPECTION"
below.

OK

Disconnect andreconnect harnesscon-
nectors inthe circuit. Thenretest.
Trouble isnot fixed.
Check ECMpinterminals fordamage
and check theconnection ofECM har-
ness connector. ReconnectECMhar-
ness connector. Thenretest.
INSPECTION END
NG
NG
Check
thefollowing.
• Harness connectors

cmD,@

• Harness foropen or
short between IACV-
FICO solenoid valveand
engine ground
If NG, repair harness or
connectors.
Replace IACV-FICD sole-
noid valve.

~i5@d
~
SEF721Q
\ Washer

~~v

err
~S~log
Plunger SEF097K:COMPONENT
INSPECTION
IACV-FICD solenoidvalve

Disconnect IACV-F1CDsolenoidvalveharness connector.
• Check forclicking soundwhenapplying 12Vdirect current
to terminals.
• Check plunger forseizing orsticking.
• Check forbroken spring.

EC-342

Page 1062 of 1701

TROUBLEDIAGNOSIS FORNON-DETECTABLE ITEMS
Cooling FanControl
SYSTEM DESCRIPTION
Cooling fancontrol

I
Vehicle speedsensor
I

Vehicle speed
Engine coolant temperature EGM
Engine coolant temperature sen- (EGGS

~

sor control
module)

I
Air conditioner switch
I

Air conditio~er "ON"signal
I

Goaling fanrelay(s)



The ECM controls thecooling fancorresponding tothe vehicle speed,engine coolant temperature, and
air conditioner ONsignal. Thecontrol system has3-step control [HIGH/LOW/OFF] onA/T models and
2-step control [ON/OFF] onM/T models.

Operation
For AIT models
Airconditioner switchis"ON".

20 80

(12) (50)

Vehicle speedkm/h(MPH)

m!lll:
Cooling fansoperate at"High" speed.
MEC772B
~u:

~ ?-
105 (221)

~ 0

2i
0
100 (212)

E

2
95(203)

C

'"

o

o

o

20 80
OJ

(12) (50) .~

Vehicle speedkm/h(MPH) ~
~: Cooling fansoperate at"Low" speed.

~LL

.3
?-
105 (221)

~o

2i
0
100 (212)

E

2
95(203)

C

'"

o

o

o

OJ

c:

.0,

c

w

0:
Cooling fansdonot operate.
For MIT models
Airconditioner switchis"OFF".

2080

(12) (50)

Vehicle speedkm/h(MPH)

~
u:
Airconditioner switchis"ON".
::J
0

1il
Z;
105 (221)

OJ
0

E
100(212)

OJ

- 95(203)

C

'"

o

o

o

OJ

c

0,

c

ill

I

20 80

(12) (50)

Vehicle speedkm/h(MPH)
~u:
::J
0

1il ;-
105 (221)

OJ
0

~ 100(212)

<1>

- 95(203)

C

&#39;&#34;

o

o

o

OJ

c

.0,

c

ill

0:
COOling fansdonot operate. m
:Cooling fansoperate at&#34;High&#34; speed.
MEC773B
EC-343

Page 1063 of 1701

TROUBLEDIAGNOSIS FORNON-DETECTABLE ITEMS~
Cooling FanControl (Cont&#39;d)

BATTERY (Via
fusible link)

M/T
models

FUSE
BLOCK
(JIB)

(El06) 30A

o
EC-COOL/F-01

Refer toEL-POWER.

@:
Models withairconditioner
... :Detectable line
for DIC
-: Non-detectable
line forOle

IIQ~OI

GY

BR
I

I
1--

BR GY

II!
]11
COOLING

n
FAN

u
RELAY-1

1biJ1bi=Jl@

LG/R
G/B

I
1----
0--
1

LG/R
I

r=::!=
<lliD
G/BG/B

I~I(][)
mm

LG/R ~COOLING ~COOLING

I
FANFAN

M
MOTOR-l
M
MOTOR-2
LG/R (E45)
rn

II-t-JI(M49) ~~
@

+@
BB

LrR
l-------6

LG/R
I

m
e.
1

- I
ECM
RFRL
(ECCS BB
CONTROL
..L_..L_

MODULE)

------ em
ern>
@D

+
<m>
2 1 L

5
~@~

lJ.l.g)
GY,GY
Refer
tolast page

(Foldout page).

@
(El0t)
,
(El06)
EC-344
em

L

HEC016

Page 1064 of 1701

TROUBLEDIAGNOSIS FORNON-DETECTABLE ITEMS[][]
Cooling FanControl (Cont&#39;d)



t
t

EC-COOL/F-02

COOLING
FAN

MOTOR-2

rn

@
tt

@:

Models withair
conditioner
... :Detectable line
for DTC
-: Non-detectable
line forDTC

____ r~-,

S S

-!- -!-

~<rn>

Refer
to

EL-POWEA.
ECM (ECCS
CONTROL

MODULE)

(IT)

i0A
FUSE
~.jffil

I
25
I
~~9~f
30A30A

(El06)
IT]
IT]

GY G/W

• --1

-~-,-I-FO~=-_I
I

SR GYG/W SRGYLG/S SAG/WLG/R

COOLINGII:!:I :!i&#39;:]JII COOLINGI&#39;:}:&#39; &#39;:f]1I:[]II COOLING/I:!:I 1:f]1&#39;:[]II

~~~AY-i ~~~~~AY-2 ~~~~~AY-3 ~~

(ffi) ~~ ~
rn ~
lbiJ
U+!J
~iC8) ~
lbiJ~

LG/R G/8G/A LGG/Y 8
@
LGG/OR S

I~ -
-tr=-
!-.J
_I _
I--~

LG ~LG/R
I

r:::::k,{jQj;r:::::k,

114.J
I~---
-l13.J
II
G/R
LG ~LG/R
wT1

I I
~~~LING~)

MOTOR-1

LG (M49) LG/R ~

1t!J~
-F6-
~cPl

LG
CEID
LG/R

I ~
1~

LG LG/R

rrToi1
rm

AFAH RFRL

AIT
models

IGNITION SWITCH
ON
or
STAAT
~ (Ei2),(Ei7),(Ei8)
~ SRSRSR ~
(E40),(E46)

t::mJ
GYGY
Refer
tolast page
(Foldout page).

~ (El0!)

,

(El06)

em
L

HEC017
EC-345

Page 1065 of 1701

TROUBLEDIAGNOSIS FORNON-DETECTABLE ITEMS
Cooling FanControl (Cont&#39;d)

• COOLING FANCIRCUIT.
DOES
COOLING FAN
ROTATE ANDSTOP
EVERY 3SECONDS
7

NEXT
II
NO
II
YES
I

MEF311F

• ACTIVE TEST.
0

COOLING FAN
OFF

= ==
MONITOR
==
=

COOLAN TEMP/S

HI

With airconditioner
C
k
00lin9fan

Q

~ID~
MEF277G
M/T

models

INSPECTION START

CHECK OVERALL FUNCTION.

(ij\
1.Turn ignition switch&#34;ON&#34;.
~ 2.Perform &#34;COOLING FAN
CIRCUIT&#34; in&#34;FUNCTION
TEST&#34; modewithCONSULT.

OR

rij\
1.Turn ignition switch&#34;ON&#34;.

\J!V
2.Select &#34;COOLING FAN&#34;in
&#34;ACTIVE TEST&#34;modewith
CONSULT.
OR

I
With airconditioner
I

1. Start engine.
2. Set temperature leveratfull cold
position.
3. Turn airconditioner switch&#34;ON&#34;.
4. Turn blower fanswitch &#34;ON&#34;.
5. Run engine atidle forafew minutes
with airconditioner operating.
6. Make surethatcooling fanoperates.

I
Without airconditioner
I

1. Start engine.
2. Keep engine speedatabout 2,000
rpm until engine iswarmed upsuffi-
ciently.
3. Make surethatcooling fanbegins to
operate duringwarm-up.

NG
CHECK POWER SUPPLY.

1. Turn airconditioner switch&#34;OFF&#34;.
2. Turn blower fanswitch &#34;OFF&#34;
(Step 1and 2are only performed for
models withairconditi.oner.)
3. Stop engine.
4. Disconnect coolingfanrelay.
5. Turn ignition switch&#34;ON&#34;.
6. Check voltage between terminals
G),
@
and ground.

Voltage: Batteryvoltage
OK

@

EC-346 OK
NG
INSPECTION
END
Check thefollowing.
• 30A fusible link
• 10A fuse
• Harness foropen or
short between fuseand
cooling fanrelay
• Harness foropen or
short between battery
and cooling fanrelay
If NG, repair harness or
connectors.

Page 1066 of 1701

TROUBLEDIAGNOSIS FORNON-DETECTABLE ITEMS
Cooling FanControl (Cont&#39;d)

@

SEF777P
MEC775B

~io ~i5

1=1
=EC=M=W
CONNECTOR
II~
CHECK
GROUND CIRCUIT.

1. Turn ignition switch&#34;OFF&#34;.
2. Disconnect coolingfanmotor-1 har-
ness connector andcooling fan
motor-2 harness connector.
3. Check harness continuity between
terminal
G)
and terminal
@,
termi-
nal
@
and body ground.

Continuity shouldexist.
(!] CHECK OUTPUT SIGNALCIRCUIT.

1. Disconnect ECMharness connector.
2. Check harness continuity between
ECM terminal
@
and terminal
@.
Continuity shouldexist.

If OK, check harness forshort.

OK

CHECK COMPONENT
(Cooling fanrelay).
Refer to&#34;COMPONENT INSPECTION&#34;,
EC-353.

OK NG
NG

NG
Repair
harness orcon-
nectors.
Check thefollowing.
• Harness connectors

(]D,@

• Harness connectors

@,@D

• Harness foropen or
short between ECM
and cooling fanrelay
If NG, repair harness or
connectors.
Replace coolingfan
relay.


CHECK COMPONENTS

SEF332Q
(Coolingfanmotors).
Refer to&#34;COMPONENT INSPECTION&#34;,
EC-353.
Disconnect andreconnect harnesscon-
nectors inthe circuit. Thenretest.
Trouble isnot fixed.
Check ECMpinterminals fordamage
and check theconnection ofECM har-
ness connector. ReconnectECMhar-
ness connector andretest.
INSPECTION END

EC-347 NG

Replace coolingfan
motors.

Page 1067 of 1701

TROUBLEDIAGNOSIS FORNON-DETECTABLE ITEMS
Cooling FanControl (Cont&#39;d)
AlT models
INSPECTION START
Checkcooling fanlow
speed control circuit.

(Go to

I
PROCEDURE A
I,

EC-350.)
NG
2. Turn ignition switch&#34;ON&#34;.
3. Perform &#34;COOLING FAN
CIRCUIT&#34; in&#34;FUNCTION
TEST&#34; modewithCONSULT.
OR
2. Turn ignition switch&#34;ON&#34;.
3. Perform &#34;COOLING FAN&#34;in
&#34;ACTIVE TEST&#34;modewith
CONSULT. OR
CHECK
COOLING FANLOW SPEED
OPERATION. 1. Disconnect coolingfan
re/ays-2
and
-3.

00

COOLING FAN
ROTATE ANDSTOP
EVERY 3SECONDS
I


COOLING FANCIRCUIT.
DOES
OK
NEXT

II
NO
II
YES
JF311F
(j)

I
With airconditioner
I

2. Start engine.
3. Set temperature leveratfull cold
position.
4. Turn airconditioner switch&#34;ON&#34;.
5. Turn blower fanswitch &#34;ON&#34;.
6. Run engine atidle forafew minutes
with airconditioner operating.
7. Make surethatcooling fanoperates
at low speed.

I
Without airconditioner
1

2. Start engine.
3. Keep engine speedatabout 2,000
rpm until engine iswarmed upsuffi-
ciently.
4. Make surethatcooling fanbegins to
operate atlow speed during warm-
up.
COOLAN
TEMPjS 88°C

ACTIVE TEST.
0

COOLING FAN
OFF

= ==
MONITOR
===

With airconditioner
lCOOtingfan

@l

~ID~

==H=I
=11L~W I

EC-348

Page 1068 of 1701

TROUBLEDIAGNOSIS FORNON-DETECTABLE ITEMS
Cooling FanControl (Cont&#39;d)
• COOLING FANCIRCUIT.
DOES
Cooling fan
MEC475B
COOLING
FAN



Check
cooling fanhigh
speed control circuit.
(Go to

I
PROCEDURE B
I.

EC-351.)
NG
OK
CHECK
COOLING FANHIGH SPEED
OPERATION.
1. Turn ignition switch&#34;OFF&#34;.
2. Reconnect coolingfanrelays-2 and
-3.
3. Disconnect coolingfanrelay-1.

(ij\
4.Turn ignition switch&#34;ON&#34;.
~ 5.Perform &#34;COOLING FAN
CIRCUIT&#34; in&#34;FUNCTION
TEST&#34; modewithCONSULT.
OR

fiii\
4.Turn ignition switch&#34;ON&#34;.
~ 5.Perform &#34;COOLING FAN&#34;in
&#34;ACTIVE TEST&#34;modewith
CONSULT.

OR

4. Turn airconditioner switch
and blower fanswitch &#34;OFF&#34;
(Models withairconditioner).
5. Disconnect enginecoolant
temperature sensorharness
connector.
6. Connect 150Qresistor to
engine coolant temperature
sensor harness connector.
7. Restart engineandmake sure
that cooling fanoperates at
higher speedthanlowspeed.

Ii
--- ---

150(1 resistor
ROTATE
ANDSTOP
EVERY 3SECONDS
&#34;I

NEXT
II
NO
II
YES
I

MEF311F
COOLAN TEMP/S

ACTIVE TEST. D
COOLING FAN
OFF

= ==
MONITOR

clTJI
LOW
1.1-

MEF314F

Ii
Ii
INSPECTIONEND
EC-349

Page 1069 of 1701

TROUBLEDIAGNOSIS FORNON-DETECTABLE ITEMS
Cooling FanControl (Cont&#39;d)
PROCEDURE A

INSPECTION START
Checkthefollowing.
• 10A fuse
• 30A fusible link
• Harness foropen or
short between cooling
fan relay-1 andfuse
• Harness foropen or
short between cooling
fan relay-1 andbattery

If
NG, repair harness or
connectors.
Repair harness orcon-
nectors.
Replace coolingfanrelay.
Check
thefollowing.
• Harness connectors

@D,@

• Harness connectors

@,QD

• Harness foropen or
short between cooling
fan relay-1 andECM

If
NG, repair harness or
connectors.

NG
NG
NG
OK
OK
@
CHECK
GROUND CIRCUIT.

1. Turn ignition switch&#34;OFF&#34;.
2. Disconnect coolingfanmotor-1 har-
ness connector andcooling fan
rnotor-2 harness connector.
3. Check harness continuity between
cooling fanrelay-1 terminal
@
and
cooling fanmotor-1 terminal
CD,
cool-
ing fan relay-1 terminal
(J)
and cool-
ing fan motor-2 terminal
CD.

Continuity shouldexist.

If OK, check harness forshort.
4. Check harness continuity between
terminal
@
and body ground.

Continuity shouldexist.

If
OK, check harness forshort.
CHECK COMPONENT
(Cooling fanrelay-1).
Refer to&#34;COMPONENT INSPECTION&#34;,
EC-353.

/
0

CHECK OUTPUT SIGNALCIRCUIT.

1. Disconnect ECMharness connector.
2. Check harness continuity between
ECM terminal
@
and terminal
@.

Continuity shouldexist.

If
OK, check harness forshort.

~

I
CHECK POWER SUPPLY.

1. Turn ignition switch&#34;OFF&#34;.
2. Disconnect coolingfanrelay-1.
3. Turn ignition switch&#34;ON&#34;.

SEF725QB
4.Check voltage between terminals
CD,

@, @
and ground withCONSULT or
tester.

Voltage: Batteryvoltage
OK
~ SEF723QA
IJ;
3

7 5

2 1

Cooling fan
relay-1

~io~io~io
~3 .~
.-fT1

7 5 ~ ~

21.

C ,. Cooling Cooling

00
Ing

f
I1 fanmotor-1 fanmotor-2

an reay-

Cooling. fan
S S
Cooling fan
motor-1
\lliJ
~motor-2

SEF727QA EC-350

Page 1070 of 1701


Replacecoolingfan
motors.
CHECK
COMPONENT
(Cooling fanmotors-1 and-2).
Refer to&#34;COMPONENT INSPECTION&#34;,
EC-353.

~
INNEer

Cooling

fan
relay-1

illi
3
7
5

2 1

TROUBLE
DIAGNOSIS FORNON-DETECTABLE ITEMS
Cooling FanControl (Cont&#39;d)

@

~

~15

ECM
~CONNECTORII

9

II

o

OK

Disconnect andreconnect harnesscon-
nectors inthe circuit. Thenretest.
Trouble isnot fixed.
Check ECMpinterminals fordamage
and check theconnection ofECM har-
ne&s connector. ReconnectECMhar-
ness connector andretest.


[ INSPECTION END

~i5
~-

clf:tb

Cooling fan
relay-2

~-

ffi:b

Cooling fan
relay-3
SEF781PPROCEDURE
B

INSPECTION START

CHECK POWER SUPPLY.

1. Turn ignition switch&#34;OFF&#34;
2. Disconnect coolingfanrelays-2 and

-3.

3. Turn ignition switch&#34;ON&#34;.
4. Check voltage between coolingfan
relay-2 terminals
CD,
@and ground,
and between coolingfanrelay-3 ter-
minals
CD,
@and ground withCON-
SUL Tor tester.

Voltage: Batteryvoltage
OK

@
NG

Check thefollowing.
• 10A fuse
• 30A fusible link
• Harness foropen or
short between cooling
fan relays-2, -3and fuse
• Harness foropen or
short between cooling
fan relays-2, -3and bat-
tery

If
NG, repair harness or
connectors.

EC-351

Page:   < prev 1-10 ... 1021-1030 1031-1040 1041-1050 1051-1060 1061-1070 1071-1080 1081-1090 1091-1100 1101-1110 ... 1710 next >