ECO mode CHRYSLER VOYAGER 2005 Workshop Manual

CHRYSLER VOYAGER 2005 Workshop Manual VOYAGER 2005 CHRYSLER CHRYSLER https://www.carmanualsonline.info/img/25/56868/w960_56868-0.png CHRYSLER VOYAGER 2005 Workshop Manual

Page 2174 of 2339

CHRYSLER VOYAGER 2005 Workshop Manual (3) Connect the HVAC wire harness connector to
the blend door actuator.
(4) Install the silencer under the driver side end of
the instrument panel (Refer to 23 - BODY/INSTRU-
MENT PANEL/INSTRUMENT PAN

Page 2175 of 2339

CHRYSLER VOYAGER 2005 Workshop Manual The blower motor relay terminals are connected to
the vehicle electrical system through a receptacle in
the Integrated Power Module (IPM). The inputs and
outputs of the blower motor relay include:
²T

Page 2177 of 2339

CHRYSLER VOYAGER 2005 Workshop Manual (4) Install the glove box (Refer to 23 - BODY/IN-
STRUMENT PANEL/GLOVE BOX - INSTALLA-
TION).
(5) Reconnect the battery negative cable.
EVAPORATOR TEMPERATURE
SENSOR
DESCRIPTION
The evaporator tempera

Page 2178 of 2339

CHRYSLER VOYAGER 2005 Workshop Manual The evaporator temperature sensor cannot be
adjusted or repaired and, if faulty or damaged, it
must be replaced.
OPERATION
The evaporator temperature sensor monitors the
temperature of the conditioned

Page 2179 of 2339

CHRYSLER VOYAGER 2005 Workshop Manual (8) Run the HVAC Cool Down test to verify system
is operating properly (Refer to 24 - HEATING & AIR
CONDITIONING - DIAGNOSIS AND TESTING).
RS MODELS
(1) Install the evaporator temperature sensor into

Page 2181 of 2339

CHRYSLER VOYAGER 2005 Workshop Manual INSTALLATION
(1) Position the mode door actuator onto the HVAC
distribution housing. If necessary, rotate the actuator
slightly to align the splines on the actuator output
shaft with those in the mode

Page 2182 of 2339

CHRYSLER VOYAGER 2005 Workshop Manual (1) Disconnect and isolate the negative battery
cable.
(2) Remove the glove box from the instrument
panel (Refer to 23 - BODY/INSTRUMENT PANEL/
GLOVE BOX - REMOVAL).
(3) Disconnect the two wire harnes

Page 2185 of 2339

CHRYSLER VOYAGER 2005 Workshop Manual INSTALLATION
(1) Position the rear A/C-heater control onto the
bezel or video screen housing, depending on applica-
tion.
(2) Install the three screws that secure the rear
A/C-heater control to the be

Page 2188 of 2339

CHRYSLER VOYAGER 2005 Workshop Manual ²The normally open terminal (87) provides a bat-
tery current output to the blower motor resistor
(manual heater-A/C control) or blower power module
(ATC heater-A/C control) through a fuse in the IPM

Page 2190 of 2339

CHRYSLER VOYAGER 2005 Workshop Manual INSTALLATION
(1) Position the rear blower motor resistor block
into the rear HVAC housing.
(2) Install the two screws that secure the rear
blower motor resistor block to the rear HVAC hous-
ing. Tight