display INFINITI M35 2006 Factory Service Manual
[x] Cancel search | Manufacturer: INFINITI, Model Year: 2006, Model line: M35, Model: INFINITI M35 2006Pages: 5621, PDF Size: 65.56 MB
Page 1346 of 5621
![INFINITI M35 2006 Factory Service Manual TROUBLE DIAGNOSIS
BRC-35
[VDC/TCS/ABS]
C
D
E
G
H
I
J
K
L
MA
B
BRC
Revision: 2006 January2006 M35/M45
5. CHECK WHEEL SENSOR HARNESS
1. Turn ignition switch OFF and disconnect malfunctioning whee INFINITI M35 2006 Factory Service Manual TROUBLE DIAGNOSIS
BRC-35
[VDC/TCS/ABS]
C
D
E
G
H
I
J
K
L
MA
B
BRC
Revision: 2006 January2006 M35/M45
5. CHECK WHEEL SENSOR HARNESS
1. Turn ignition switch OFF and disconnect malfunctioning whee](/img/42/57023/w960_57023-1345.png)
TROUBLE DIAGNOSIS
BRC-35
[VDC/TCS/ABS]
C
D
E
G
H
I
J
K
L
MA
B
BRC
Revision: 2006 January2006 M35/M45
5. CHECK WHEEL SENSOR HARNESS
1. Turn ignition switch OFF and disconnect malfunctioning wheel
sensor connector E41(FR-RH), E59(FR-LH), B101(RR-RH),
B102(RR-LH) and ABS actuator and electric unit (control unit)
connector E30.
2. Check continuity between terminals. (Also check continuity
when steering wheel is turned right and left and when sensor
harness inside the wheel house is moved.)
OK or NG
OK >> GO TO 6.
NG >>
Repair or replace malfunctioning components.
Perform the self-diagnosis, and make sure that the result shows “NO DTC IS DETECTED”.
6. CHECK WHEEL SENSOR
1. Replace wheel sensor that resulted in malfunction by self-diagnosis.
2. Reconnect connectors, drive vehicle at 30 km/h (19 MPH) or more for approximately 1 minute, and then
perform self-diagnosis.
Is above displayed on the self-diagnosis display?
OK >> INSPECTION END
NG >>
Replace ABS actuator and electric unit (control unit).
Perform the self-diagnosis, and make sure that the result shows “NO DTC IS DETECTED”.
SFIA3030E
Power supply circuit Signal circuit Ground circuit
WheelABS actuator
and electric
unit (control
unit)Wheel sensorABS actua-
tor and elec-
tric unit
(control unit)Wheel sensorABS actua-
tor and elec-
tric unit
(control
unit)
(signal)Ground
Front RH 9 1 10 2 9, 10
— Front LH 26 1 5 2 26, 5
Rear RH 7 1 29 2 7, 29
Rear LH 6 1 27 2 6, 27
Power supply circuit : Yes
Signal circuit : Yes
Ground circuit : No
Page 1347 of 5621
![INFINITI M35 2006 Factory Service Manual BRC-36
[VDC/TCS/ABS]
TROUBLE DIAGNOSIS
Revision: 2006 January2006 M35/M45
Inspection 2: Engine SystemNFS000QM
INSPECTION PROCEDURE
1. CHECK SELF-DIAGNOSIS RESULTS
Check self-diagnosis results.
Is abov INFINITI M35 2006 Factory Service Manual BRC-36
[VDC/TCS/ABS]
TROUBLE DIAGNOSIS
Revision: 2006 January2006 M35/M45
Inspection 2: Engine SystemNFS000QM
INSPECTION PROCEDURE
1. CHECK SELF-DIAGNOSIS RESULTS
Check self-diagnosis results.
Is abov](/img/42/57023/w960_57023-1346.png)
BRC-36
[VDC/TCS/ABS]
TROUBLE DIAGNOSIS
Revision: 2006 January2006 M35/M45
Inspection 2: Engine SystemNFS000QM
INSPECTION PROCEDURE
1. CHECK SELF-DIAGNOSIS RESULTS
Check self-diagnosis results.
Is above displayed on the self-diagnosis display?
YES >> GO TO 2.
NO >> INSPECTION END
2. CHECK ENGINE SYSTEM
1. Perform ECM self-diagnosis. Repair or replace items indicated, then perform ECM self-diagnosis again.
Refer to EC-100, "
TROUBLE DIAGNOSIS" (VQ35DE), EC-811, "TROUBLE DIAGNOSIS" (VK45DE).
2. Perform ABS actuator and electric unit (control unit) self-diagnosis.
OK or NG
OK >> INSPECTION END
NG >>
Repair or replace malfunctioning components.
Perform the self-diagnosis, and make sure that the result shows NO DTC IS DETECTED.
Inspection 3: ABS Actuator and Electric Unit (Control Unit)NFS000QN
INSPECTION PROCEDURE
1. CHECK SELF-DIAGNOSIS RESULTS
Check self-diagnosis results.
CAUTION:
Replace ABS actuator and electric unit (control unit) when self-diagnostic result shows items other
than those above.
Is above displayed on the self-diagnosis display?
YES >>Replace ABS actuator and electric unit (control unit).
Perform the self-diagnosis, and make sure that the result shows NO DTC IS DETECTED.
NO >> INSPECTION END
Self-diagnosis results
ENGINE SIGNAL 1
ENGINE SIGNAL 2
ENGINE SIGNAL 3
ENGINE SIGNAL 4
ENGINE SIGNAL 6
Self-diagnosis results
CONTROLLER FAILURE
EMERGENCY BRAKE
VARIANT CODING
Page 1348 of 5621
![INFINITI M35 2006 Factory Service Manual TROUBLE DIAGNOSIS
BRC-37
[VDC/TCS/ABS]
C
D
E
G
H
I
J
K
L
MA
B
BRC
Revision: 2006 January2006 M35/M45
Inspection 4: ABS Actuator and Electric Unit (Control Unit) Power Supply and
Ground Circuit
NFS000 INFINITI M35 2006 Factory Service Manual TROUBLE DIAGNOSIS
BRC-37
[VDC/TCS/ABS]
C
D
E
G
H
I
J
K
L
MA
B
BRC
Revision: 2006 January2006 M35/M45
Inspection 4: ABS Actuator and Electric Unit (Control Unit) Power Supply and
Ground Circuit
NFS000](/img/42/57023/w960_57023-1347.png)
TROUBLE DIAGNOSIS
BRC-37
[VDC/TCS/ABS]
C
D
E
G
H
I
J
K
L
MA
B
BRC
Revision: 2006 January2006 M35/M45
Inspection 4: ABS Actuator and Electric Unit (Control Unit) Power Supply and
Ground Circuit
NFS000QO
INSPECTION PROCEDURE
1. CHECK SELF-DIAGNOSIS RESULTS
Check self-diagnosis results.
Is above displayed on the self-diagnosis display?
YES >> GO TO 2.
NO >> INSPECTION END
2. CHECK CONNECTOR
1. Turn ignition switch OFF and disconnect ABS actuator and electric unit (control unit) connector E30,
check terminal for deformation, disconnection, looseness, and so on. If any malfunction is found, repair or
replace terminal.
2. Reconnect connector and perform self-diagnosis.
OK or NG
OK >> INSPECTION END
NG >> GO TO 3.
3. CHECK ABS ACTUATOR AND ELECTRIC UNIT (CONTROL UNIT) POWER SUPPLY CIRCUIT AND
GROUND CIRCUIT
1. Turn ignition switch OFF and disconnect ABS actuator and electric unit (control unit) connector E30.
2. Turn ignition switch ON or OFF and check voltage between ABS
actuator and electric unit (control unit) harness connector E30
terminal 28 and ground.
Self-diagnosis results
BATTERY VOLTAGE [ABNORMAL]
SFIA3032E
ABS actuator and electric unit (control unit) Ground Condition Voltage
28 —Ignition switch ONBattery voltage
(Approx. 12 V)
Ignition switch OFF Approx. 0 V
Page 1349 of 5621
![INFINITI M35 2006 Factory Service Manual BRC-38
[VDC/TCS/ABS]
TROUBLE DIAGNOSIS
Revision: 2006 January2006 M35/M45
3. Turn ignition switch OFF and check continuity between ABS
actuator and electric unit (control unit) harness connector E30
t INFINITI M35 2006 Factory Service Manual BRC-38
[VDC/TCS/ABS]
TROUBLE DIAGNOSIS
Revision: 2006 January2006 M35/M45
3. Turn ignition switch OFF and check continuity between ABS
actuator and electric unit (control unit) harness connector E30
t](/img/42/57023/w960_57023-1348.png)
BRC-38
[VDC/TCS/ABS]
TROUBLE DIAGNOSIS
Revision: 2006 January2006 M35/M45
3. Turn ignition switch OFF and check continuity between ABS
actuator and electric unit (control unit) harness connector E30
terminal 1, 4 and ground.
OK or NG
OK >>Check battery for terminal looseness, low voltage, etc. If any malfunction is found, repair mal-
functioning parts.
Perform the self-diagnosis, and make sure that the result shows NO DTC IS DETECTED.
NG >>
Repair or replace malfunctioning components.
Perform the self-diagnosis, and make sure that the result shows NO DTC IS DETECTED.
Inspection 5: ABS Motor and Motor Relay CircuitNFS000QP
INSPECTION PROCEDURE
1. CHECK SELF-DIAGNOSIS RESULTS
Check self-diagnosis results.
Is above displayed on the self-diagnosis display?
YES >> GO TO 2.
NO >> INSPECTION END
2. CHECK CONNECTOR
1. Turn ignition switch OFF and disconnect ABS actuator and electric unit (control unit) connector E30,
check terminal for deformation, disconnection, looseness, and so on. If any malfunction is found, repair or
replace terminal.
2. Reconnect connector and perform self-diagnosis.
OK or NG
OK >> INSPECTION END
NG >> GO TO 3.
SFIA3033E
ABS actuator and electric unit (control unit) Ground Continuity
1, 4 — Yes
Self-diagnosis results
PUMP MOTOR
Page 1351 of 5621
![INFINITI M35 2006 Factory Service Manual BRC-40
[VDC/TCS/ABS]
TROUBLE DIAGNOSIS
Revision: 2006 January2006 M35/M45
Inspection 6: Solenoid, VDC Change-Over Valve and Actuator Relay CircuitNFS000QQ
INSPECTION PROCEDURE
1. CHECK SELF-DIAGNOSIS INFINITI M35 2006 Factory Service Manual BRC-40
[VDC/TCS/ABS]
TROUBLE DIAGNOSIS
Revision: 2006 January2006 M35/M45
Inspection 6: Solenoid, VDC Change-Over Valve and Actuator Relay CircuitNFS000QQ
INSPECTION PROCEDURE
1. CHECK SELF-DIAGNOSIS](/img/42/57023/w960_57023-1350.png)
BRC-40
[VDC/TCS/ABS]
TROUBLE DIAGNOSIS
Revision: 2006 January2006 M35/M45
Inspection 6: Solenoid, VDC Change-Over Valve and Actuator Relay CircuitNFS000QQ
INSPECTION PROCEDURE
1. CHECK SELF-DIAGNOSIS RESULTS
Check self-diagnosis results.
Is above displayed on the self-diagnosis display?
YES >> GO TO 2.
NO >> INSPECTION END
2. CHECK CONNECTOR
1. Turn ignition switch OFF and disconnect ABS actuator and electric unit (control unit) connector E30,
check terminal for deformation, disconnection, looseness, and so on. If any malfunction is found, repair or
replace terminal.
2. Reconnect connector and perform self-diagnosis.
OK or NG
OK >> INSPECTION END
NG >> GO TO 3.
3. CHECK SOLENOID, VDC CHANGE-OVER VALVE AND ACTUATOR RELAY POWER SUPPLY CIR-
CUIT
1. Turn ignition switch OFF and disconnect ABS actuator and electric unit (control unit) connector E30.
2. Check voltage between ABS actuator and electric unit (control
unit) harness connector E30 terminal 3 and ground.
Self-diagnosis results
FR RH IN ABS SOL
FR RH OUT ABS SOL
FR LH IN ABS SOL
FR LH OUT ABS SOL
RR RH IN ABS SOL
RR RH OUT ABS SOL
RR LH IN ABS SOL
RR LH OUT ABS SOL
USV LINE [FL-RR]
USV LINE [FR-RL]
HSV LINE [FL-RR]
HSV LINE [FR-RL]
MAIN RELAY
SFIA3035E
ABS actuator and electric unit (control unit) Ground Voltage
3 — Battery voltage (Approx. 12 V)
Page 1352 of 5621
![INFINITI M35 2006 Factory Service Manual TROUBLE DIAGNOSIS
BRC-41
[VDC/TCS/ABS]
C
D
E
G
H
I
J
K
L
MA
B
BRC
Revision: 2006 January2006 M35/M45
OK or NG
OK >> GO TO 4.
NG >>
Repair or replace malfunctioning components.
Perform the self-diagnos INFINITI M35 2006 Factory Service Manual TROUBLE DIAGNOSIS
BRC-41
[VDC/TCS/ABS]
C
D
E
G
H
I
J
K
L
MA
B
BRC
Revision: 2006 January2006 M35/M45
OK or NG
OK >> GO TO 4.
NG >>
Repair or replace malfunctioning components.
Perform the self-diagnos](/img/42/57023/w960_57023-1351.png)
TROUBLE DIAGNOSIS
BRC-41
[VDC/TCS/ABS]
C
D
E
G
H
I
J
K
L
MA
B
BRC
Revision: 2006 January2006 M35/M45
OK or NG
OK >> GO TO 4.
NG >>
Repair or replace malfunctioning components.
Perform the self-diagnosis, and make sure that the result shows NO DTC IS DETECTED.
4. CHECK SOLENOID, VDC CHANGE-OVER VALVE, ACTUATOR RELAY GROUND CIRCUIT
Check continuity between ABS actuator and electric unit (control
unit) harness connector E30 terminal 1, 4 and ground.
OK or NG
OK >>Replace ABS actuator and electric unit (control unit).
Perform the self-diagnosis, and make sure that the result shows NO DTC IS DETECTED.
NG >>
Repair or replace malfunctioning components.
Perform the self-diagnosis, and make sure that the result shows NO DTC IS DETECTED.
Inspection 7: Pressure Sensor CircuitNFS000QR
INSPECTION PROCEDURE
1. CHECK SELF-DIAGNOSIS RESULTS
Check self-diagnosis results.
Is above displayed on the self-diagnosis display?
YES >>Replace ABS actuator and electric unit (control unit).
Perform the self-diagnosis, and make sure that the result shows NO DTC IS DETECTED.
NO >> INSPECTION END
Inspection 8: Steering Angle Sensor CircuitNFS000QS
INSPECTION PROCEDURE
1. CHECK SELF-DIAGNOSIS RESULTS
Check self-diagnosis results.
Is above displayed on the self-diagnosis display?
YES >> GO TO 2.
NO >> INSPECTION END
SFIA3033E
ABS actuator and electric unit (control unit) Ground Continuity
1, 4 — Yes
Self-diagnosis results
PRESS SEN CIRCUIT
Self-diagnosis results
ST ANG SEN CIRCUIT
Page 1354 of 5621
![INFINITI M35 2006 Factory Service Manual TROUBLE DIAGNOSIS
BRC-43
[VDC/TCS/ABS]
C
D
E
G
H
I
J
K
L
MA
B
BRC
Revision: 2006 January2006 M35/M45
4. CHECK DATA MONITOR
1. Turn ignition switch OFF and connect the steering angle sensor connector a INFINITI M35 2006 Factory Service Manual TROUBLE DIAGNOSIS
BRC-43
[VDC/TCS/ABS]
C
D
E
G
H
I
J
K
L
MA
B
BRC
Revision: 2006 January2006 M35/M45
4. CHECK DATA MONITOR
1. Turn ignition switch OFF and connect the steering angle sensor connector a](/img/42/57023/w960_57023-1353.png)
TROUBLE DIAGNOSIS
BRC-43
[VDC/TCS/ABS]
C
D
E
G
H
I
J
K
L
MA
B
BRC
Revision: 2006 January2006 M35/M45
4. CHECK DATA MONITOR
1. Turn ignition switch OFF and connect the steering angle sensor connector and ABS actuator and electric
unit (control unit) connector.
2. Select “STR ANGLE SIG” in “Data Monitor” and check steering angle sensor signal.
OK or NG
OK >> Perform self-diagnosis.
NG >>
Replace spiral cable (steering angle sensor) and adjust neutral position of steering angle sen-
sor. Refer to BRC-6, "
Adjustment of Steering Angle Sensor Neutral Position" .
Perform the self-diagnosis, and make sure that the result shows NO DTC IS DETECTED.
Inspection 9: Park/Neutral Position (PNP) Switch CircuitNFS000QT
INSPECTION PROCEDURE
1. CHECK SELF-DIAGNOSIS RESULTS
Check self-diagnosis results.
Is above displayed on the self-diagnosis display?
YES >> GO TO 2.
NO >> INSPECTION END
2. CHECK DATA MONITOR
Select “SLCT LVR POSI” in “Data Monitor” and check Park/Neutral position switch signal.
OK or NG
OK >>Replace ABS actuator and electric unit (control unit).
Perform the self-diagnosis, and make sure that the result shows NO DTC IS DETECTED.
NG >> GO TO 3.Steering conditionSTR ANGLE SIG
(Data monitor)
Driving straight – 2.5
to + 2.5
Tu r n 9 0 to right Approx.+ 90
Tu r n 9 0 to left Approx.– 90
Self-diagnosis results
PNP POSI SIG
Selector lever positionSLCT LVR POSI
(Data monitor)
P position P
R position R
N position N
D position D
Page 1355 of 5621
![INFINITI M35 2006 Factory Service Manual BRC-44
[VDC/TCS/ABS]
TROUBLE DIAGNOSIS
Revision: 2006 January2006 M35/M45
3. CHECK PARK/NEUTRAL POSITION (PNP) SWITCH
Perform Park/Neutral position switch inspection. Refer to AT- 11 3 , " INFINITI M35 2006 Factory Service Manual BRC-44
[VDC/TCS/ABS]
TROUBLE DIAGNOSIS
Revision: 2006 January2006 M35/M45
3. CHECK PARK/NEUTRAL POSITION (PNP) SWITCH
Perform Park/Neutral position switch inspection. Refer to AT- 11 3 , "](/img/42/57023/w960_57023-1354.png)
BRC-44
[VDC/TCS/ABS]
TROUBLE DIAGNOSIS
Revision: 2006 January2006 M35/M45
3. CHECK PARK/NEUTRAL POSITION (PNP) SWITCH
Perform Park/Neutral position switch inspection. Refer to AT- 11 3 , "
DTC P0705 PARK/NEUTRAL POSITION
SWITCH" .
OK or NG
OK >>Replace ABS actuator and electric unit (control unit).
Perform the self-diagnosis, and make sure that the result shows NO DTC IS DETECTED.
NG >>
Repair or replace malfunctioning components.
Perform the self-diagnosis, and make sure that the result shows NO DTC IS DETECTED.
Inspection 10: Stop Lamp Switch CircuitNFS000QU
INSPECTION PROCEDURE
1. CHECK SELF-DIAGNOSIS RESULTS
Check self-diagnosis results.
Is above displayed on the self-diagnosis display?
YES >> GO TO 2.
NO >> INSPECTION END
2. CHECK CONNECTOR
1. Turn ignition switch OFF and disconnect stop lamp switch connector E124 and ABS actuator and electric
unit (control unit) connector E30, check terminal for deformation, disconnection, looseness, and so on. If
any malfunction is found, repair or replace terminal.
2. Reconnect connectors securely.
3. Start engine.
4. Repeat pumping brake pedal carefully several times, and perform self-diagnosis.
OK or NG
OK >> INSPECTION END
NG >> GO TO 3.
Self-diagnosis results
STOP LAMP SW
Page 1356 of 5621
![INFINITI M35 2006 Factory Service Manual TROUBLE DIAGNOSIS
BRC-45
[VDC/TCS/ABS]
C
D
E
G
H
I
J
K
L
MA
B
BRC
Revision: 2006 January2006 M35/M45
3. CHECK STOP LAMP SWITCH CIRCUIT
1. Turn ignition switch OFF and disconnect ABS actuator and elect INFINITI M35 2006 Factory Service Manual TROUBLE DIAGNOSIS
BRC-45
[VDC/TCS/ABS]
C
D
E
G
H
I
J
K
L
MA
B
BRC
Revision: 2006 January2006 M35/M45
3. CHECK STOP LAMP SWITCH CIRCUIT
1. Turn ignition switch OFF and disconnect ABS actuator and elect](/img/42/57023/w960_57023-1355.png)
TROUBLE DIAGNOSIS
BRC-45
[VDC/TCS/ABS]
C
D
E
G
H
I
J
K
L
MA
B
BRC
Revision: 2006 January2006 M35/M45
3. CHECK STOP LAMP SWITCH CIRCUIT
1. Turn ignition switch OFF and disconnect ABS actuator and electric unit (control unit) connector E30.
2. Check voltage between ABS actuator and electric unit (control
unit) harness connector E30 terminal 30 and ground.
OK or NG
OK >> Perform self-diagnosis.
NG >>
Repair or replace stop lamp switch circuit.
Perform the self-diagnosis, and make sure that the result shows NO DTC IS DETECTED.
Inspection 11: Yaw Rate/Side G Sensor CircuitNFS000QV
CAUTION:
Sudden turns (such as spin turns, acceleration turns), drifting, etc., when VDC function is off (VDC
OFF switch "ON") may cause yaw rate/side G sensor system to indicate a malfunction. However,
this is not a malfunction, if normal operation can be resumed after restarting engine. Then erase
memory of self-diagnosis.
If vehicle is on turn-table at entrance to parking garage, or on other moving surface, VDC OFF
indicator lamp may illuminate and CONSULT-II self-diagnosis may indicate yaw rate sensor sys-
tem malfunction. However, in this case there is no malfunction in yaw rate sensor system. Take
vehicle off of turn-table or other moving surface, and start engine. Results will return to normal.
And after doing spin turns or acceleration turns with VDC function is being off (VDC OFF switch
“ON”), too, the results will return to a normal condition by re-starting vehicle.
INSPECTION PROCEDURE
1. CHECK SELF-DIAGNOSIS RESULTS
Check self-diagnosis results.
Is above displayed on the self-diagnosis display?
YES >> GO TO 2.
NO >> INSPECTION END
SFIA3038E
ABS actuator and electric
unit (control unit)Ground Condition Voltage
30 —Brake pedal depressedBattery voltage
(Approx. 12 V)
Brake pedal not depressed Approx. 0V
Self-diagnosis results
YAW RATE SENSOR
SIDE G-SEN CIRCUIT
Page 1359 of 5621
![INFINITI M35 2006 Factory Service Manual BRC-48
[VDC/TCS/ABS]
TROUBLE DIAGNOSIS
Revision: 2006 January2006 M35/M45
Inspection 12: Brake Fluid Level Switch CircuitNFS000QW
CAUTION:
Check brake fluid level in brake reservoir tank before starti INFINITI M35 2006 Factory Service Manual BRC-48
[VDC/TCS/ABS]
TROUBLE DIAGNOSIS
Revision: 2006 January2006 M35/M45
Inspection 12: Brake Fluid Level Switch CircuitNFS000QW
CAUTION:
Check brake fluid level in brake reservoir tank before starti](/img/42/57023/w960_57023-1358.png)
BRC-48
[VDC/TCS/ABS]
TROUBLE DIAGNOSIS
Revision: 2006 January2006 M35/M45
Inspection 12: Brake Fluid Level Switch CircuitNFS000QW
CAUTION:
Check brake fluid level in brake reservoir tank before starting inspection.
INSPECTION PROCEDURE
1. CHECK SELF-DIAGNOSIS RESULTS
1. Check brake fluid level in brake reservoir tank. If brake fluid level is low, refill brake fluid.
2. Check self-diagnosis results.
Is above displayed on the self-diagnosis display?
YES >> GO TO 2.
NO >> INSPECTION END
2. CHECK CONNECTOR
1. Turn ignition switch OFF and disconnect brake fluid level switch connector E23 and ABS actuator and
electric unit (control unit) connector E30, check terminal for deformation, disconnection, looseness, and
so on. If any malfunction is found, repair or replace terminal.
2. Reconnect connector and perform self-diagnosis.
OK or NG
OK >> INSPECTION END
NG >> GO TO 3.
3. CHECK BRAKE FLUID LEVEL SWITCH
1. Turn ignition switch OFF and disconnect brake fluid level switch connector E23.
2. Check continuity between brake fluid level switch connector E23
terminal 1 and 2.
OK or NG
OK >> GO TO 4.
NG >>
Brake fluid level switch is malfunctioning. Replace reservoir tank. Refer to BR-15, "BRAKE
MASTER CYLINDER" .
Perform the self-diagnosis, and make sure that the result shows NO DTC IS DETECTED.
Self-diagnosis results
BR FLUID LEVEL LOW
SFIA2966E
Brake fluid level switch Condition Continuity
1, 2When brake fluid is full in the reservoir tank No
When brake fluid is empty in the reservoir tank Yes