Page 1471 of 2395

4 CHECK POWER SUPPLY FOR MULTI-REMOTE CONTROL RELAY
1. Disconnect multi-remote control relay connector.
2. Check voltage between terminal 1 and ground.
SEL326X
OK or NG
OK©GO TO 5.
NG©Check the following.
I15A fuse [No. 20, located in fuse block (J/B)]
IHarness for open or short between multi-remote control relay and fuse
5 CHECK MULTI-REMOTE CONTROL RELAY CIRCUIT
1. Disconnect multi-remote control relay connector.
2. Check voltage between terminals 3 and 5.
3. Check voltage between terminals 6 and 7.
SEL327X
OK or NG
OK©Check harness for open or short between smart entrance control unit and multi-remote
control relay.
NG©Check the following.
IHarness for open or short between multi-remote control relay and fuse
IHarness for open or short between multi-remote control relay and turn signal lamps
MULTI-REMOTE CONTROL SYSTEM
Trouble Diagnoses (Cont'd)
EL-286 
Page 1472 of 2395

HORN REMINDER CHECK=NBEL0115S11
1 CHECK HORN
Check if horn sounds with horn switch.
Does horn operate?
Ye s©GO TO 2.
No©Check horn circuit.
2 CHECK HORN REMINDER OPERATION
1. Disconnect smart entrance control unit connector.
2. Apply ground to smart entrance control unit terminal 19.
SEL328X
Refer to wiring diagram in EL-276.
OK or NG
OK©Replace smart entrance control unit.
NG©Check harness for open or short between smart entrance control unit and horn relay.
GI
MA
EM
LC
EC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
IDX
MULTI-REMOTE CONTROL SYSTEM
Trouble Diagnoses (Cont'd)
EL-287 
Page 1473 of 2395

INTERIOR ROOM LAMP OPERATION CHECK=NBEL0115S09
1 CHECK INTERIOR ROOM LAMP
Check if the interior room lamp switch is in the ªONº position and the lamp illuminates.
Does interior room lamp illuminate?
Ye s©GO TO 2.
No©Check the following.
IHarness for open or short between smart entrance control unit and interior room lamp
IInterior room lamp
2 CHECK INTERIOR ROOM LAMP CIRCUIT
When interior room lamp switch is ªDOORº position, check voltage across smart entrance control unit terminal 8 and
ground.
SEL329X
Refer to wiring diagram in EL-274.
OK or NG
OK©GO TO 3.
NG©Repair harness between smart entrance control unit and interior room lamp.
3 CHECK CONTROL UNIT OUTPUT
Push unlock button of remote controller with key removed and all doors closed, and check voltage across smart entrance
control unit terminal 8 and ground.
SEL330X
OK or NG
OK©Check system again.
NG©Replace smart entrance control unit.
MULTI-REMOTE CONTROL SYSTEM
Trouble Diagnoses (Cont'd)
EL-288 
Page 1474 of 2395

ID Code Entry Procedure=NBEL0222REMOTE CONTROLLER ID SET UP WITH CONSULT-IINBEL0222S01NOTE:
If a remote controller is lost, the ID code of the lost remote
controller must be erased to prevent unauthorized use. When
the ID code of a lost remote controller is not known, all con-
troller ID codes should be erased. After all ID codes are
erased, the ID codes of all remaining and/or new remote con-
trollers must be re-registered.
SEL331X
1. Turn ignition switch ªOFFº.
2. Connect CONSULT-II to the data link connector.
PBR455D
3. Turn ignition switch ªONº.
4. Touch ªSTARTº.
SEL332X
5. Touch ªSMART ENTRANCEº.
SEL333X
6. Touch ªMULTI REMOTE ENTº.
GI
MA
EM
LC
EC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
IDX
MULTI-REMOTE CONTROL SYSTEM
ID Code Entry Procedure
EL-289 
Page 1475 of 2395

SEL334X
7. Touch ªWORK SUPPORTº.
SEL335X
8. The items are shown on the figure at left can be set up.
IªREMO CONT ID CONFIRº
Use this mode to confirm if a remote controller ID code is reg-
istered or not.
IªREMO CONT ID REGISTº
Use this mode to register a remote controller ID code.
NOTE:
Register the ID code when remote controller or smart entrance
control unit is replaced, or when additional remote controller
is required.
IªREMO CONT ID ERASURº
Use this mode to erase a remote controller ID code.
MULTI-REMOTE CONTROL SYSTEM
ID Code Entry Procedure (Cont'd)
EL-290 
Page 1476 of 2395

REMOTE CONTROLLER ID SET UP WITHOUT
CONSULT-II
NBEL0222S03
SEL332WA
GI
MA
EM
LC
EC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
IDX
MULTI-REMOTE CONTROL SYSTEM
ID Code Entry Procedure (Cont'd)
EL-291 
Page 1477 of 2395

NOTE:
IIf a remote controller is lost, the ID code of the lost remote
controller must be erased to prevent unauthorized use. A spe-
cific ID code can be erased with CONSULT-II. However, when
the ID code of a lost remote controller is not known, all con-
troller ID codes should be erased. After all ID codes are
erased, the ID codes of all remaining and/or new remote con-
trollers must be re-registered.
To erase all ID codes in memory, register one ID code (remote
controller) four times. After all ID codes are erased, the ID
codes of all remaining and/or new remote controllers must be
re-registered.
IWhen registering an additional remote controller, the existing
ID codes in memory may or may not be erased. If four ID
codes are stored in memory, when an additional code is
registered, only the oldest code is erased. If less than four ID
codes are stored in memory, when an additional ID code is
registered, the new ID code is added and no ID codes are
erased.
IIf you need to activate more than two additional new remote
controllers, repeat the procedure ªAdditional ID code entryº for
each new remote controller.
IEntry of maximum four ID codes is allowed. When more than
four ID codes are entered, the oldest ID code will be erased.
IEven if the same ID code that is already in the memory is input,
the same ID code can be entered. The code is counted as an
additional code.
MULTI-REMOTE CONTROL SYSTEM
ID Code Entry Procedure (Cont'd)
EL-292 
Page 1478 of 2395

Remote Controller Battery ReplacementNBEL0118
SEL732W
GI
MA
EM
LC
EC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
IDX
MULTI-REMOTE CONTROL SYSTEM
Remote Controller Battery Replacement
EL-293 
Page 1480 of 2395

System DescriptionNBEL0120DESCRIPTIONNBEL0120S011. Operation FlowNBEL0120S0101
SEL334W
2. Setting The Theft Warning SystemNBEL0120S0102Initial condition
1) Close all doors.
2) Close hood and glass hatch.
Disarmed phase
When the theft warning system is in the disarmed phase, the security indicator lamp blinks every 2.6 seconds.
Pre-armed phase and armed phase
The theft warning system turns into the ªpre-armedº phase when hood, glass hatch and all doors are closed
and the doors are locked by key or multi-remote controller. (The security indicator lamp illuminates.)
After about 30 seconds, the system automatically shifts into the ªarmedº phase (the system is set). (The
security indicator lamp blinks every 2.6 seconds.)
3. Canceling The Set Theft Warning SystemNBEL0120S0103When the following 1) or 2) operation is performed, the armed phase is canceled.
1) Unlock the doors with the key or multi-remote controller.
2) Open the glass hatch with the key.
4. Activating The Alarm Operation of The Theft Warning SystemNBEL0120S0104Make sure the system is in the armed phase. (The security indicator lamp blinks every 2.6 seconds.)
When any of the following operations is performed, the system sounds the horns and flashes the headlamps
for about 50 seconds.
1) Engine hood, glass hatch or any door is opened before unlocking door with key or multi-remote control-
ler.
2) Door is unlocked without using key or multi-remote controller.
3) Disconnecting and connecting the battery connector before canceling armed phase.
POWER SUPPLY AND GROUNDNBEL0120S07Power is supplied at all times
Ithrough 7.5A fuse [No. 24, located in the fuse block (J/B)]
Ito security indicator lamp terminal 1, and
Ito smart entrance control unit terminal 10.
With the ignition switch in the ON or START position, power is supplied
Ithrough 7.5A fuse [No. 11, located in the fuse block (J/B)]
GI
MA
EM
LC
EC
FE
AT
TF
PD
AX
SU
BR
ST
RS
BT
HA
SC
IDX
THEFT WARNING SYSTEM
System Description
EL-295 
Page 1481 of 2395
![INFINITI QX4 2001  Factory Owners Manual Ito smart entrance control unit terminal 33.
With the ignition switch in the ACC or ON position, power is supplied
Ithrough 10A fuse [No. 10, located in the fuse block (J/B)]
Ito smart entrance contro INFINITI QX4 2001  Factory Owners Manual Ito smart entrance control unit terminal 33.
With the ignition switch in the ACC or ON position, power is supplied
Ithrough 10A fuse [No. 10, located in the fuse block (J/B)]
Ito smart entrance contro](/img/42/57027/w960_57027-1480.png)
Ito smart entrance control unit terminal 33.
With the ignition switch in the ACC or ON position, power is supplied
Ithrough 10A fuse [No. 10, located in the fuse block (J/B)]
Ito smart entrance control unit terminal 21.
Ground is supplied
Ito smart entrance control unit terminal 16
Ithrough body grounds M77 and M111.
INITIAL CONDITION TO ACTIVATE THE SYSTEMNBEL0120S02The operation of the theft warning system is controlled by the doors, hood and glass hatch.
To activate the theft warning system, the smart entrance control unit must receive signals indicating the doors,
hood and glass hatch are closed and the doors are locked.
When a door is open, smart entrance control unit terminal 28, 29 or 40 receives a ground signal from each
door switch.
When a door is unlocked, smart entrance control unit terminal 26, 36 or 37 receives a ground signal from ter-
minal 4 of each door unlock sensor or terminal 1 of back door unlock sensor.
When the hood is open, smart entrance control unit terminal 27 receives a ground signal
Ifrom terminal 1 of the hood switch
Ithrough body grounds E13 and E41.
When the glass hatch is open, smart entrance control unit terminal 38 receives a ground signal
Ifrom terminal 1 of the glass hatch switch
Ithrough body grounds D210, B11 and B22.
When the doors are locked with key or multi-remote controller and none of the described conditions exist, the
theft warning system will automatically shift to armed mode.
THEFT WARNING SYSTEM ACTIVATION (WITH KEY OR REMOTE CONTROLLER USED TO
LOCK DOORS)
NBEL0120S03If the key is used to lock doors, terminal 41 receives a ground signal
Ifrom terminal 3 of the key cylinder switch LH
Ithrough back grounds M77 and M111
Ifrom terminal 1 of the back door key cylinder switch
Ithrough body grounds B11, B22 and D210.
If this signal or lock signal from remote controller is received by the smart entrance control unit, the theft
warning system will activate automatically.
Once the theft warning system has been activated, smart entrance control unit terminal 31 supplies ground to
terminal 2 of the security indicator lamp.
The security lamp will illuminate for approximately 30 seconds and then blink.
Now the theft warning system is in armed phase.
THEFT WARNING SYSTEM ALARM OPERATIONNBEL0120S04The theft warning system is triggered by
Iopening a door
Iopening the hood or the glass hatch
Iunlocking door without using the key or multi-remote controller.
Once the theft warning system is in armed phase, if the smart entrance control unit receives a ground signal
at terminal 26, 36, 37 (door unlock sensor), 28, 29, 40 (door switch), 38 (glass hatch switch) or 27 (hood
switch), the theft warning system will be triggered. The headlamps flash and the horn sounds intermittently.
Power is supplied at all times
Ithrough 7.5A fuse (No. 52, located in fuse and fusible link box)
Ito horn relay terminals 1 and 3.
Ithrough 10A fuse (No. 54, located in fuse and fusible link box)
Ito horn relay terminal 6.
When the theft warning system is triggered, ground is supplied intermittently
Ifrom terminal 4 of the smart entrance control unit
Ito headlamp relay LH and RH terminal 2 and
Ifrom terminal 19 of the smart entrance control unit
THEFT WARNING SYSTEM
System Description (Cont'd)
EL-296