TROUBLE DIAGNOSIS
SRS-21
C
D
E
F
G
I
J
K
L
MA
B
SRS
Revision: 2006 January2006 M35/M45
Trouble Diagnosis with CONSULT-IINHS00097
DIAGNOSTIC PROCEDURE 2
CAUTION:
If CONSULT-II is used with no connection of CONSULT-II CONVERTER, malfunctions might be
detected in self-diagnosis depending on control unit which carry out CAN communication.
1. Touch “SELF-DIAG [CURRENT]”.
2. Diagnostic code is displayed on “SELF-DIAG [CURRENT]”.
a. If no malfunction is detected on “SELF-DIAG [CURRENT]” even
though malfunction is detected in “SRS Operation Check”,
check the battery voltage. If the battery voltage is less than 9 V,
charge or replace the battery. Then go to SRS-25, "
DIAGNOS-
TIC PROCEDURE 3" . If the battery voltage is OK, go to SRS-
27, "DIAGNOSTIC PROCEDURE 4 (CONTINUED FROM
DIAGNOSTIC PROCEDURE 2)" to diagnose the following
cases:
Self-diagnosis result “SELF-DIAG [PAST]” (previously stored
in the memory) might not be erased after repair.
The SRS system malfunctions intermittently.
CONSULT-II Diagnostic Code Chart (“SELF-DIAG [CURRENT]”)
SRS697
SHIA0203E
SRS701
Diagnostic item ExplanationRepair order
“Recheck SRS at each replacement”
NO DTC IS
DETECTED.When malfunction is
indicated by the “AIR
BAG” warning lamp in
User mode.
Low battery voltage (Less than 9 V)Go to SRS-25, "DIAGNOSTIC PRO-
CEDURE 3" after charging the bat-
tery.
Self-diagnosis result “SELF-DIAG
[PAST]” (previously stored in the
memory) might not be erased after
repair.
Intermittent malfunction has been
detected in the past.
Go to SRS-27, "DIAGNOSTIC PRO-
CEDURE 4 (CONTINUED FROM
DIAGNOSTIC PROCEDURE 2)" .
Go to SRS-27, "DIAGNOSTIC PRO-
CEDURE 5" .
No malfunction is detected. —

Page 5508 of 5621

AIR BREATHER HOSE
TF-43
C
E
F
G
H
I
J
K
L
MA
B
TF
Revision: 2006 January2006 M35/M45
AIR BREATHER HOSEPFP:31098
Removal and InstallationNDS000E3
Refer to the figure for air breather hose removal and installation information.
CAUTION:
Make sure there are no pinched or restricted areas on the air breather hose caused by bending or
winding when installing it.
Be sure to insert air breather hose to transfer tube (metal connector) until hose end reaches the
tube's base and another hose end reaches the tube bend R portion of A/T fluid charging pipe.
SDIA2408E