INFINITI QX4 2001  Factory Service Manual Diagnostic ProcedureNBEC0196
1 RETIGHTEN GROUND SCREWS
1. Turn ignition switch ªOFFº.
2. Loosen and retighten engine ground screws.
SEF959Y
©GO TO 2.
2 CHECK CKPS (POS) POWER SUPPLY CIRCUIT
1. Disc

Page 876 of 2395

INFINITI QX4 2001  Factory Service Manual 10 CHECK CRANKSHAFT POSITION SENSOR (POS)-II
1. Reconnect disconnected harness connectors.
2. Turn ignition switch ªONº.
3. Check voltage between ECM terminal 85 and ground by briefly touching the s

Page 878 of 2395

INFINITI QX4 2001  Factory Service Manual Possible CauseNBEC0494IHarness or connectors
[The camshaft position sensor (PHASE) circuit is open or
shorted.]
ICamshaft position sensor (PHASE)
IStarter motor (Refer to SC section.)
IStarting system

Page 880 of 2395

INFINITI QX4 2001  Factory Service Manual Diagnostic ProcedureNBEC0202
1 CHECK STARTING SYSTEM
Turn ignition switch to ªSTARTº position.
Does the engine turn over?
Does the starter motor operate?
YesorNo
Ye s©GO TO 2.
No©Check starting sy

Page 886 of 2395

INFINITI QX4 2001  Factory Service Manual 6 CHECK IGNITION SPARK
1. Turn ignition switch ªOFFº.
2. Disconnect ignition coil assembly from rocker cover.
3. Connect a known good spark plug to the ignition coil assembly.
4. Place end of spark

Page 899 of 2395

INFINITI QX4 2001  Factory Service Manual 18 CHECK ABSOLUTE PRESSURE SENSOR
1. Remove absolute pressure sensor with its harness connector connected.
SEF961Y
2. Remove hose from absolute pressure sensor.
3. Install a vacuum pump to absolute pr

Page 900 of 2395

INFINITI QX4 2001  Factory Service Manual 20 CHECK EVAP CONTROL SYSTEM PRESSURE SENSOR
1. Remove EVAP control system pressure sensor with its harness connector connected.
CAUTION:
INever apply force to the air hole protector of the sensor if

Page 906 of 2395

INFINITI QX4 2001  Factory Service Manual Diagnostic ProcedureNBEC0227
1 CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE POWER SUPPLY CIRCUIT
1. Turn ignition switch ªOFFº.
2. Disconnect EVAP canister purge volume control solenoid v

Page 907 of 2395

INFINITI QX4 2001  Factory Service Manual 3 CHECK EVAP CANISTER PURGE VOLUME CONTROL SOLENOID VALVE OUTPUT SIGNAL CIRCUIT
FOR OPEN AND SHORT
1. Turn ignition switch ªOFFº.
2. Disconnect ECM harness connector.
3. Check harness continuity bet

Page 910 of 2395

INFINITI QX4 2001  Factory Service Manual Possible CauseNBEC0512IHarness or connectors
(The valve circuit is open or shorted.)
IEVAP canister vent control valve
DTC Confirmation ProcedureNBEC0232NOTE:
If ªDTC Confirmation Procedureº has bee