Page 763 of 3061

BL-52
< SERVICE INFORMATION >
REMOTE KEYLESS ENTRY SYSTEM
Check continuity between back door latch connector terminal 8 and
ground.
OK or NG
OK >> Back door switch circuit is OK.
NG >> Repair or replace harness.
Keyfob Battery and Function CheckINFOID:0000000003532928
1.CHECK KEYFOB BATTERY
Remove battery and measure voltage across battery positive and negative terminals, (+) and (−).
NOTE:
Keyfob does not function if battery is not set correctly.
OK or NG
OK >> GO TO 2.
NG >> Replace battery.
2.CHECK KEYFOB FUNCTION
With CONSULT-II
Check keyfob function in “DATA MONITOR” mode with CONSULT-II.
When pushing each button of keyfob, the corresponding monitor item should be
turned as follows.
Without CONSULT-II
Check keyfob function using Remote Keyless Entry Tester J-43241.
OK or NG
OK >> WITH CONSULT-II: Keyfob, remote keyless entry receiver and wiring harness between BCM and
remote keyless entry receiver are OK. Replace BCM. Refer to BCS-24, "
BCM" .
OK >> WITHOUT CONSULT-II: Keyfob is OK. Further inspection is necessary. Refer to BL-47, "
Trouble
Diagnosis" .
NG >> WITH CONSULT-II: Further inspection is necessary. Refer to BL-47, "
Trouble Diagnosis".
NG >> WITHOUT CONSULT-II: Replace keyfob. Refer to BL-56, "
ID Code Entry Procedure". 8 - Ground : Continuity should exist.
LIIA0828E
Voltage : 2.5V - 3.0V
SEL237W
Condition Monitor item
Pushing LOCK KEYLESS LOCK : ON
Pushing UNLOCK KEYLESS UNLOCK : ON
Keep pushing UNLOCKRKE KEEP UNLK turns
to ON 3 seconds after
UNLOCK button is
pushed.
Pushing PANIC KEYLESS PANIC : ON
Pushing LOCK and UNLOCK
at the same timeRKE LCK-UNLCK : ON
Pushing Power Back Door KEYLESS PBD : ON
LIIA1487E
Page 765 of 3061

BL-54
< SERVICE INFORMATION >
REMOTE KEYLESS ENTRY SYSTEM
2. Check continuity between remote keyless entry receiver con-
nector M120 terminals 1, 2, 4 and BCM connector M18 termi-
nals 18, 19, 20.
3. Check continuity between remote keyless entry receiver termi-
nals 1, 2 and 4 and ground.
OK or NG
OK >> Replace remote keyless entry receiver.
NG >> Repair or replace harness.
ACC Power CheckINFOID:0000000003532930
1.CHECK ACC POWER
With CONSULT-II
Check "ACC ON SW" in DATA MONITOR mode with CONSULT–II. Refer to BL-45, "
CONSULT-II Application
Item".
Without CONSULT-II
Check voltage between BCM connector M18 terminal 11 and
ground.
OK or NG
OK >> ACC power circuit is OK.
NG >> Check the following:
• 10A fuse [No. 4, located in fuse block (J/B)]
• Harness for open or short.
IPDM E/R Operation CheckINFOID:0000000003532931
1.CHECK IPDM E/R INPUT VOLTAGE1 - 18 : Continuity should exist.
2 - 20 : Continuity should exist.
4 - 19 : Continuity should exist.
1 - Ground : Continuity should not exist.
2 - Ground : Continuity should not exist.
4 - Ground : Continuity should not exist.
WIIA0308E
Monitor Item Condition
ACC ON SWIgnition switch position ACC : ON
Ignition switch position OFF : OFF
PIIA3367E
ConnectorTe r m i n a l s
ConditionVoltage (V)
(Approx.)
(+) (–)
M18 11 GroundACC Battery voltage
OFF 0
PIIA7002E
Page 785 of 3061

BL-74
< SERVICE INFORMATION >
VEHICLE SECURITY (THEFT WARNING) SYSTEM
Check voltage between BCM connector M18 or M19 terminals 12,
13, 42, 43, 47, 48 and ground.
OK or NG
OK >> Door switch circuit is OK.
NG >> GO TO 2.
2.CHECK DOOR SWITCH CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect door switch and BCM.
3. Check continuity between door switch connector (B) B8 (front LH), B108 (front RH), B18 (rear LH), B116
(rear RH) terminal 2 or back door latch connector (C) D503 terminal 7 and BCM connectors (A) M18, M19
terminals 12, 13, 43, 47 and 48.
4. Check continuity between door switch connector (B) B8 (front
LH), B108 (front RH), B18 (rear LH), B116 (rear RH) terminal 2
or back door latch connector (C) D503 terminal 7 and ground.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness.
3.CHECK DOOR SWITCHES
FRONT AND REAR DOORS
Connector ItemTe r m i n a l s
ConditionVoltage (V)
(Approx.)
(+) (–)
M19Glass hatch
ajar switch42
GroundOpen
↓
Closed0
↓
Battery voltage back door
latch (door
ajar switch)43
Front door
switch LH47
Rear door
switch LH48
M18Front door
switch RH12
Rear door
switch RH13
LIIA1451E
2 - 12 : Continuity should exist.
2 - 13 : Continuity should exist.
2 - 47 : Continuity should exist.
2 - 48 : Continuity should exist.
7 - 43 : Continuity should exist.
2 - Ground : Continuity should not exist.
7 - Ground : Continuity should not exist.
WIIA0750E
Page 786 of 3061

VEHICLE SECURITY (THEFT WARNING) SYSTEM
BL-75
< SERVICE INFORMATION >
C
D
E
F
G
H
J
K
L
MA
B
BL
N
O
P
Check continuity between front or rear door switch terminal 2 and
exposed metal of switch while pressing and releasing switch.
BACK DOOR
Check continuity between back door latch connector (A) D503 termi-
nals 7 and 8 while pressing (closing back door) and releasing (open-
ing back door) switch.
OK or NG
OK >> (Front and rear doors) Switch circuit is OK.
OK >> (Back door) GO TO 4.
NG >> Replace door switch.
4.CHECK BACK DOOR SWITCH GROUND
Check continuity between back door latch connector terminal 8 and
ground.
OK or NG
OK >> Back door switch circuit is OK.
NG >> Repair or replace harness.
Hood Switch CheckINFOID:0000000003532950
1.CHECK HOOD SWITCH
Check hood switch and hood fitting condition.
OK or NG
OK >> GO TO 2.
NG >> Adjust installation of hood switch.
2.CHECK HOOD SWITCH INPUT SIGNAL
With CONSULT-II
Check "HOOD SW" in "DATA MONITOR" mode with CONSULT-II.Door switch is released : Continuity should exist.
Door switch is pushed : Continuity should not exist.
WIIA0644E
When back door is open : Continuity should exist.
When back door is closed : Continuity should not exist.
WIIA0752E
8 - Ground : Continuity should exist.
LIIA0828E
When hood is open : HOOD SW ON
When hood is closed : HOOD SW OFF
LIIA0038E
Page 788 of 3061

VEHICLE SECURITY (THEFT WARNING) SYSTEM
BL-77
< SERVICE INFORMATION >
C
D
E
F
G
H
J
K
L
MA
B
BL
N
O
P
2. Check voltage between BCM harness connector M18 terminal
23 and ground.
OK or NG
OK >> Security indicator lamp is OK.
NG >> GO TO 2.
2.SECURITY INDICATOR LAMP CHECK
Check security indicator lamp condition.
Refer to DI-5
.
OK or NG
OK >> GO TO 3.
NG >> Replace combination meter (security indicator lamp). Refer to DI-5
.
3.CHECK HARNESS CONTINUITY
1. Turn ignition switch OFF.
2. Disconnect BCM and combination meter (security indicator lamp).
3. Check continuity between BCM connector (A) M18 terminal 23
and combination meter (security indicator lamp) harness con-
nector (B) M24 terminal 28.
4. Check continuity between BCM connector (A) M18 terminal 23
and ground.
OK or NG
OK >> Check the following:
• 10A fuse [No. 19, located in fuse block (J/B)]
• Harness for open or short between combination meter (security indicator lamp) and fuse
NG >> Repair or replace harness.
Front Door Lock Assembly LH (Key Cylinder Switch) CheckINFOID:0000000003532952
1.CHECK FRONT DOOR LOCK ASSEMBLY LH (KEY CYLINDER SWITCH)
With CONSULT-II
Check front door lock assembly LH (key cylinder switch) ("KEY CYL LK-SW") and ("KEY CYL UN-SW) in
DATA MONITOR mode in CONSULT–II.Refer to BL-70, "
CONSULT-II Function (BCM)".
• When key inserted in front key cylinder is turned to LOCK:
• When key inserted in front key cylinder is turned to UNLOCK:
Without CONSULT-II
ConnectorTe r m i n a l s
ConditionVoltage (V)
(Approx.)
(+) (-)
M18 23 GroundON 0
OFFBattery volt-
age
LIIA0523E
23 - 28 : Continuity should exist.
23 - ground : Continuity should not exist.
LIIA2253E
KEY CYL LK-SW : ON
KEY CYL UN-SW : ON
LIIA0188E
Page 789 of 3061

BL-78
< SERVICE INFORMATION >
VEHICLE SECURITY (THEFT WARNING) SYSTEM
Check voltage between main power window and door lock/unlock switch connector D7 terminals 4, 6 and
ground.
OK or NG
OK >> Front door lock assembly LH (key cylinder switch) signal is OK.
NG >> GO TO 2.
2.CHECK DOOR KEY CYLINDER SWITCH LH GROUND HARNESS
Check continuity between front door lock assembly LH (key cylinder
switch) connector (A) D14 terminal 5 and body ground.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness.
3.CHECK DOOR KEY CYLINDER SWITCH LH
Check continuity between front door lock assembly LH (key cylinder
switch) terminals.
OK or NG
OK >> GO TO 4.
NG >> Replace front door lock assembly LH (key cylinder switch). Refer to BL-110, "
Removal and Instal-
lation".
4.CHECK DOOR KEY CYLINDER HARNESS
ConnectorTe r m i n a l s
ConditionVoltage (V)
(Approx.)
(+) (–)
D74
GroundNeutral/Unlock 5
Lock 0
6Neutral/Lock 5
Unlock 0
LIIA0566E
Connector Terminals Continuity
D14 5 – Ground Yes
WIIA0755E
Terminals Condition Continuity
1 – 5 Key is turned to UNLOCK or neutral. No
Key is turned to LOCK. Yes
5 – 6Key is turned to LOCK or neutral. No
Key is turned to UNLOCK. Yes
LIIA1573E
Page 794 of 3061

AUTOMATIC BACK DOOR SYSTEM
BL-83
< SERVICE INFORMATION >
C
D
E
F
G
H
J
K
L
MA
B
BL
N
O
P Reversal
The door will reverse direction during power open or close operation if the automatic door main switch, keyfob
or back door close switch is operated. A chime will sound to announce the reversal.
Anti-Pinch Function
• During auto operation, if an object is detected in the door's path, a warning chime sounds and the back door
operates in the reverse direction to prevent pinching.
• During auto close operation, if an object is detected by the pinch strips in the door's path, a warning chime
sounds and the back door operates in the open direction until it is fully open.
Gas Stay Check
• During each power open operation, the back door control unit monitors motor current draw to determine if
the gas stays are functioning properly.
• If a malfunction of the gas stays is detected, the back door control unit will close the back door while sound-
ing the warning chime. The back door cannot be opened using the switches until the gas stay malfunction is
repaired.
Warning Functions
• The hazard warning lamps flash and a warning chime is sounded according to the back door operating state,
operations, and conditions.
Auto Back Door Operation Enable Conditions
Control When Operating Enable Conditions Not Met During Power Open/Close
Control When Operating Enable Conditions No Longer Met
Operation Power liftgate switch Remote keyless entry Back door handle switchBack door
close switch
Operating
directionFully closed →
openFully open →
closedFully closed →
openFully open →
closedFully closed →
openFully open →
closedFully open →
closed
Close
switchCANCEL or NEUTRAL NEUTRAL NEUTRAL
Vehicle stop
conditionA/T selector le-
ver in P or N
range and vehi-
cle speed less
than 2 km/h or
ignition switch
in OFF position—A/T selector le-
ver in P or N
range and vehi-
cle speed less
than 2 km/h or
ignition switch
in OFF position—A/T selector le-
ver in P or N
range and vehi-
cle speed less
than 2 km/h or
ignition switch in
OFF position——
Battery volt-
ageApprox. 11V or more
Back door
lock status————Unlocked——
Glass hatch Closed
Items Operation condition Not met case Control
A/T selector lever P positionP or N position with ignition ON
or any position with ignition OFFOtherContinue power open or close,
but sounds warning chime.
Back door close switch NEUTRAL CANCEL
Cancels power open/close op-
eration or door will release to
manual mode. Voltage drop 11V or more11 > V > 9
9 > V > reset voltage
reset voltage > V No power function available
Handle switch Normal (GND) Error (OPEN)No operation. Cancel power
open/close release to manual.
Glass hatch Closed OFFCancels power door open oper-
ation, door will release to manu-
al mode.
Page 803 of 3061

BL-92
< SERVICE INFORMATION >
AUTOMATIC BACK DOOR SYSTEM
Terminal and Reference Value for BCM
INFOID:0000000003532962
Refer to BCS-11, "Terminal and Reference Value for BCM".
Trouble Diagnosis ProcedureINFOID:0000000003532963
1. Check the trouble symptom and customer's requests.
2. Understand outline of system. Refer to BL-80, "
System Description".
3. Confirm system operation.
4. Perform self-diagnosis procedures. Refer to BL-93, "
Self-Diagnosis Procedure".
5. Refer to diagnosis chart by symptom, repair or replace any malfunctioning parts. Refer to BL-94, "
Diagno-
sis Chart".
6. Inspection End.
15 O/L Open switch signal While fully closing back door
17 GR Glass hatch ajar signalGlass hatch OPEN 0
Glass hatch CLOSED 5
18 GR/R Park switchP or N position (Ignition is ON) 0
Other (Ignition is ON) 9
19 BR/B Pinch strip RHDetecting obstruction 0
Other 5
20 V/G Pinch strip LHDetecting obstruction 0
Other 5
21 W/V Power window serial link —
22 BR Half switch signal Back door half latch position
23 L/W Power liftgate switchON 0
OFF 5
26 V Back door handle switch signalHandle operation 0
Other Battery voltage Te r m i n a l Wire Col-
orItem ConditionVoltage (V)
(Approx.)
WIIA1047E
PIIA2344E
PIIA2169E
Page 807 of 3061

BL-96
< SERVICE INFORMATION >
AUTOMATIC BACK DOOR SYSTEM
2.POWER LIFTGATE SWITCH POWER SUPPLY CIRCUIT INSPECTION
1. Turn ignition switch OFF.
2. Check voltage between power liftgate switch connector M92 ter-
minal 1 and ground.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness.
3.POWER LIFTGATE SWITCH SIGNAL INSPECTION
1. Turn ignition switch OFF.
2. While operating the power liftgate switch, check voltage
between back door control unit connector B55 terminal 23 and
ground.
OK or NG
OK >> Switch is OK.
NG >> GO TO 4.
4.POWER LIFTGATE SWITCH CIRCUIT INSPECTION
1. Disconnect power liftgate switch and back door control unit connector.
2. Check continuity between power liftgate switch connector M92
terminal 1 and back door control unit connector B55 terminal 23.
OK or NG
OK >> GO TO 5.
NG >> Repair or replace harness.
5.POWER LIFTGATE SWITCH GROUND INSPECTION
Check continuity between power liftgate switch connector terminal 2
and ground.
OK or NG
OK >> Replace the power liftgate switch.
NG >> Repair or replace harness.
GLASS HATCH AJAR SWITCH CHECK
1 - Ground :Approx. battery voltage
LIIA1551E
Te r m i n a l s
ConditionVoltage (V)
(Approx.)
(+) (-)
23 GroundPower liftgate
switchON 0
OFF 5
LIIA0802E
1 - 23 : Continuity should exist.
LIIA1064E
2 - Ground : Continuity should exist.
LIIA1065E
Page 808 of 3061

AUTOMATIC BACK DOOR SYSTEM
BL-97
< SERVICE INFORMATION >
C
D
E
F
G
H
J
K
L
MA
B
BL
N
O
P
1.CHECK GLASS HATCH AJAR SWITCH INPUT SIGNAL
With CONSULT-II
Check glass hatch ajar switch ("TRNK OPN MNTR") in DATA MONITOR mode with CONSULT–II. Refer to
BL-24, "
CONSULT-II Function (BCM)".
• When glass hatch is open:
• When glass hatch is closed:
Without CONSULT-II
Check voltage between BCM connector M19 terminal 42 and ground.
OK or NG
OK >> System is OK.
NG >> GO TO 2.
2.CHECK GLASS HATCH AJAR SWITCH CIRCUIT
1. Turn ignition switch OFF.
2. Disconnect glass hatch ajar switch, BCM and back door control unit.
3. Check continuity between glass hatch ajar switch connector D707 terminal + and BCM connector M19 ter-
minal 42.
4. Check continuity between glass hatch ajar switch connector
D707 terminal + and back door control unit connector B55 termi-
nal 17.
5. Check continuity between glass hatch ajar switch connector
D707 terminal + and ground.
OK or NG
OK >> GO TO 3.
NG >> Repair or replace harness.
3.CHECK GLASS HATCH AJAR SWITCH
1. Disconnect glass hatch ajar switch connector.
2. Check continuity between glass hatch ajar switch connector terminal and ground.TRNK OPN MNTR : ON
TRNK OPN MNTR : OFF
WIIA0108E
Connector ItemTe r m i n a l s
ConditionVoltage (V)
(Approx.)
(+) (–)
M19 BCM 42 GroundOpen
↓
Closed0
↓
Battery voltage
LIIA1149E
+ - 42 : Continuity should exist
+ - 17 : Continuity should exist
+ - Ground : Continuity should not exist
LIIA1547E