check MITSUBISHI LANCER 2005 Workshop Manual

MITSUBISHI LANCER 2005 Workshop Manual LANCER 2005 MITSUBISHI MITSUBISHI https://www.carmanualsonline.info/img/19/57321/w960_57321-0.png MITSUBISHI LANCER 2005 Workshop Manual

Page 485 of 788

MITSUBISHI LANCER 2005  Workshop Manual 55-1
GROUP 55
HEATER, AIR 
CONDITIONER AND 
VENTILATION
CONTENTS
SERVICE SPECIFICATIONS . . . . . . .55-3
LUBRICANTS  . . . . . . . . . . . . . . . . . .55-3
SPECIAL TOOLS . . . . . . . . . . . . . .

Page 486 of 788

MITSUBISHI LANCER 2005  Workshop Manual 55-2
ON-VEHICLE SERVICE . . . . . . . . . . .55-69
SIGHT GLASS REFRIGERANT 
LEVEL TEST . . . . . . . . . . . . . . . . . . . . . . . . 55-69
MAGNETIC CLUTCH TEST . . . . . . . . . . . . 55-69
COMPRESS

Page 488 of 788

MITSUBISHI LANCER 2005  Workshop Manual SPECIAL TOOLS
HEATER, AIR CONDITIONER AND VENTILATION55-4
SPECIAL TOOLS
M1552000600312
Tool Tool number Name Application
MB991367 Special spanner Armature mounting nut of 
compressor removal and 
inst

Page 489 of 788

MITSUBISHI LANCER 2005  Workshop Manual TROUBLESHOOTING
HEATER, AIR CONDITIONER AND VENTILATION55-5
TROUBLESHOOTING
DIAGNOSIS TROUBLESHOOTING FLOWM1552009600364
Refer to GROUP 00, How to Use 
Troubleshooting/Inspection Service Points P.00-5

Page 491 of 788

MITSUBISHI LANCER 2005  Workshop Manual TROUBLESHOOTING
HEATER, AIR CONDITIONER AND VENTILATION55-7
DIAGNOSIS
STEP 1. Check the defogger and A/C operations.
Q: Do the defogger and A/C work normally?
YES : 
Go to Step 2.
NO <L.H.D.> : Refer

Page 492 of 788

MITSUBISHI LANCER 2005  Workshop Manual TROUBLESHOOTING
HEATER, AIR CONDITIONER AND VENTILATION55-8
STEP 4. Check the wiring harness between C-107 
outside/inside air selection damper control motor 
connector terminal No.7 and the ignition

Page 493 of 788

MITSUBISHI LANCER 2005  Workshop Manual TROUBLESHOOTING
HEATER, AIR CONDITIONER AND VENTILATION55-9
Prior to the wiring harness inspection, check 
intermediate connector C-106, joint connector C-35, 
junction block connectors C-209 and C-21

Page 494 of 788

MITSUBISHI LANCER 2005  Workshop Manual TROUBLESHOOTING
HEATER, AIR CONDITIONER AND VENTILATION55-10
STEP 6. Check the wiring harness between C-107 
outside/inside air selection damper control motor 
connector (terminals 6 and 4) and C-139

Page 496 of 788

MITSUBISHI LANCER 2005  Workshop Manual TROUBLESHOOTING
HEATER, AIR CONDITIONER AND VENTILATION55-12
COMMENTS ON TROUBLE SYMPTOM
If cool air is not distributed when the A/C switch is on, 
the air thermo sensor or the A/C compressor relay 
s

Page 497 of 788

MITSUBISHI LANCER 2005  Workshop Manual TROUBLESHOOTING
HEATER, AIR CONDITIONER AND VENTILATION55-13
STEP 5. Voltage measurement at the B-114 A/C 
compressor connector.
(1) Disconnect the connector, and measure at the 
wiring harness side.