SSANGYONG MY2002
7C-20 MANUAL & SEMIAUTO-HVAC
KAA7C210
KAA7C220
KAA7C230
Removal & Installation Procedure
1. Disconnect the inlet and outlet pipes of condenser.
Notice: Before disconnection, evacuate the
refrigerant from the system.
Notice: When installing, check the O-ring and
apply compressor oil.
2. Remove the mounting bolts (2EA) and condenser
assembly.
Installation Notice
3. Remove the main condenser fan from condenser.
Tightening Torque Inlet Side to 10 - 15Nm
(7 - 11 lb-ft)
Outlet Side to 4 - 6 Nm
(35 - 53 lb-in)
4. Installation should follow the removal procedure
in the reverse order.
Tightening Torque4 - 6 Nm
(35 - 53 lb-in)
SSANGYONG MY2002
7C-22 MANUAL & SEMIAUTO-HVAC
3. Disconnect the inlet and outlet pipes of receiver
drier.
Notice: When installing, check the O-ring and
apply the compressor oil.
Installation Notice
4. Remove the bracket bolt and then remove the
receiver drier.
Installation Notice
5. Installation should follow the removal procedure
in the reverse order.
KAA7C250
Removal & Installation Procedure
1. Disconnect the negative(-) terminal from the
battery.
2. Discharge refrigerant from the system.
Notice: By connecting a manifold gauge
connection hose to High/Low pressure line,
discharge the refrigerant.
Tightening Torque4 - 6 Nm
(35 - 53 lb-in)
Tightening Torque5 - 8 Nm
(44 - 71 lb-in)