NISSAN TEANA 2008 Service Manual

Page 1281 of 5121

TRUNK LID OPENER ACTUATOR
DLK-65
< COMPONENT DIAGNOSIS >[WITH INTELLIGENT KEY SYSTEM]
C
D
E
F
G
H
I
J
L
MA
B
DLK
N
O
P
TRUNK LID OPENER ACTUATOR
DescriptionINFOID:0000000003794860
Trunk lid opener actuator open trunk lid from BCM.
Component Function CheckINFOID:0000000003794861
1.CHECK FUNCTION
1. Perform Active Test (“TRUNK/GLASS HATCH”) with CONSULT-III.
2. Touch “OPEN” and check that trunk lid opens.
Is the inspection result normal?
YES >> Trunk lid opener actuator is OK.
NO >> Refer to DLK-65, "
Diagnosis Procedure".
Diagnosis ProcedureINFOID:0000000003794862
1.CHECK TRUNK LID OPENER INPUT SIGNAL
1. Turn ignition switch OFF.
2. Disconnect trunk lid lock assembly.
3. Check voltage between trunk lid lock assembly harness connector and ground.
Is the inspection result normal?
YES >> GO TO 3.
NO >> GO TO 2.
2.CHECK TRUNK LID OPENER ACTUATOR CIRCUIT
1. Disconnect BCM connector.
2. Check continuity between BCM harness connector and trunk lid lock assembly (trunk lid opener actuator)
harness connector.
3. Check continuity between BCM harness connector and ground.
Is the inspection result normal?
YES >> Replace BCM. Refer to BCS-78, "Removal and Installation".
NO >> Repair or replace harness.
3.CHECK TRUNK LID OPENER ACTUATOR GROUND CIRCUIT
Check continuity between trunk lid lock assembly (trunk lid opener actuator) harness connector and ground.
(+)
(–) ConditionVoltage (V)
(Approx.) Trunk lid lock assembly
(trunk lid opener actuator)
Connector Terminal
T5 2 Ground Trunk lid opener switch is ON 0 → Battery voltage → 0
BCMTrunk lid lock assembly
(trunk lid opener actuator)
Continuity
Connector Terminal Connector Terminal
M120 23 T5 2 Existed
BCM
GroundContinuity
Connector Terminal
M120 23 Not existed

Page 1282 of 5121

DLK-66
< COMPONENT DIAGNOSIS >[WITH INTELLIGENT KEY SYSTEM]
TRUNK LID OPENER ACTUATOR
Is the inspection normal?
YES >> Replace trunk lid lock assembly. Refer to DLK-214, "TRUNK LID ASSEMBLY : Removal and
Installation"
NO >> Repair or replace harness.
Trunk lid lock assembly
GroundContinuity
Connector Terminal
T5 3 Existed

Page 1283 of 5121

REMOTE KEYLESS ENTRY RECEIVER
DLK-67
< COMPONENT DIAGNOSIS >[WITH INTELLIGENT KEY SYSTEM]
C
D
E
F
G
H
I
J
L
MA
B
DLK
N
O
P
REMOTE KEYLESS ENTRY RECEIVER
DescriptionINFOID:0000000003794867
Receives Intelligent Key operation and transmits to BCM.
Component Function CheckINFOID:0000000003794868
1.CHECK FUNCTION
With CONSULT-III
Check remote keyless entry receiver (“RKE OPE COUN1”) in Data Monitor mode with CONSULT-III.
Is the inspection result normal?
YES >> Remote keyless entry receiver is OK.
NO >> Refer to DLK-67, "
Diagnosis Procedure".
Diagnosis ProcedureINFOID:0000000003794869
1.CHECK REMOTE KEYLESS ENTRY RECEIVER OUTPUT SIGNAL
1. Turn ignition switch OFF.
2. Check signal between remote keyless entry receiver harness connector and ground with oscilloscope.
Is the inspection result normal?
YES >> GO TO 2.
NO >> GO TO 3.
2.CHECK REMOTE KEYLESS ENTRY RECEIVER CIRCUIT 1
1. Disconnect BCM connector and remote keyless entry receiver connector.
2. Check continuity between BCM harness connector and remote keyless entry receiver harness connector.
3. Check continuity between BCM harness connector and ground.
Monitor item Condition
RKE OPE COUN1 Checks whether value changes when operating Intelligent Key.
(+)
(–) ConditionSignal
(Reference value) Remote keyless entry receiver
Connector Terminal
M78 2 GroundWaiting
(All doors closed)
When signal is received
(All doors closed)
JMKIA0064GB
JMKIA0065GB
BCM Remote keyless entry receiver
Continuity
Connector Terminal Connector Terminal
M122 83 M78 2 Existed

Page 1284 of 5121

DLK-68
< COMPONENT DIAGNOSIS >[WITH INTELLIGENT KEY SYSTEM]
REMOTE KEYLESS ENTRY RECEIVER
Is the inspection result normal?
YES >> INSPECTION END.
NO >> Repair or replace harness.
3.CHECK REMOTE KEYLESS ENTRY RECEIVER POWER SUPPLY
Check signal between remote keyless entry receiver harness connector and ground with oscilloscope.
Is the inspection result normal?
YES >> GO TO 5.
NO >> GO TO 4.
4.CHECK REMOTE KEYLESS ENTRY RECEIVER CIRCUIT 2
1. Disconnect BCM connector and remote keyless entry receiver.
2. Check continuity between BCM harness connector and remote keyless entry receiver harness connector.
3. Check continuity between BCM harness connector and ground.
Is the inspection result normal?
YES >> Replace BCM. Refer to BCS-78, "Removal and Installation".
NO >> Repair or replace harness.
5.CHECK REMOTE KEYLESS ENTRY RECEIVER CIRCUIT 1
1. Disconnect BCM connector and remote keyless entry receiver.
2. Check continuity between BCM connector and remote keyless entry receiver connector.
3. Check continuity between BCM harness connector and ground.
BCM
GroundContinuity
Connector Terminal
M122 83 Not existed
(+)
(–)Signal
(Reference value) Remote keyless entry receiver
Connector Terminal
M78 4 Ground
JMKIA0064GB
BCM Remote keyless entry receiver
Continuity
Connector Terminal Connector Terminal
M122 103 M78 4 Existed
BCM
GroundContinuity
Connector Terminal
M122 103 Not existed
BCM Remote keyless entry receiver
Continuity
Connector Terminal Connector Terminal
M123 137 M78 1 Existed

Page 1285 of 5121

REMOTE KEYLESS ENTRY RECEIVER
DLK-69
< COMPONENT DIAGNOSIS >[WITH INTELLIGENT KEY SYSTEM]
C
D
E
F
G
H
I
J
L
MA
B
DLK
N
O
P
Is the inspection result normal?
YES >> GO TO 6.
NO >> Repair or replace harness.
6.CHECK REMOTE KEYLESS ENTRY RECEIVER GROUND CIRCUIT 2
1. Connect remote keyless entry receiver connector.
2. Check continuity between remote keyless entry receiver harness connector and ground.
Is the inspection result normal?
YES >> Replace remote keyless entry receiver. Refer to DLK-244, "Removal and Installation".
NO >> Replace BCM. Refer to BCS-78, "
Removal and Installation".
BCM
GroundContinuity
Connector Terminal
M122 137 Not existed
Remote keyless entry receiver
GroundContinuity
Connector Terminal
M78 1 Existed

Page 1286 of 5121

DLK-70
< COMPONENT DIAGNOSIS >[WITH INTELLIGENT KEY SYSTEM]
TRUNK LID OPENER SWITCH
TRUNK LID OPENER SWITCH
DescriptionINFOID:0000000003794870
Output trunk lid open signal to BCM.
Component Function CheckINFOID:0000000003794871
1.CHECK FUNCTION
Check trunk lid opener switch (“TR/BD OPEN SW”) in “Data Monitor mode with CONSULT-III.
Is the inspection result normal?
YES >> Trunk lid opener switch is OK.
NO >> Refer to DLK-70, "
Diagnosis Procedure".
Diagnosis ProcedureINFOID:0000000003794872
1.CHECK TRUNK LID OPENER INPUT SIGNAL
1. Turn ignition switch OFF.
2. Disconnect trunk lid opener switch connector.
3. Check signal between trunk lid opener switch harness connector and ground with oscilloscope.
Is the inspection result normal?
YES >> GO TO 3.
NO >> GO TO 2.
2.CHECK TRUNK LID OPENER SWITCH CIRCUIT
1. Disconnect BCM connector.
2. Check continuity between BCM harness connector and trunk lid opener switch harness connector.
3. Check continuity between BCM harness connector and ground.
Is the inspection result normal?
YES >> Replace BCM. Refer to BCS-78, "Removal and Installation".
Monitor item Condition
TR/BD OPEN SWTrunk lid opener switch is pressed: ON
Trunk lid opener switch is released: OFF
(+)
(–)Signal
(Reference value) Trunk lid opener switch
Connector Terminal
M25 1 Ground
JPMIA0011GB
BCM Trunk lid opener switch
Continuity
Connector Terminal Connector Terminal
M121 67 M25 1 Existed
BCM
GroundContinuity
Connector Terminal
M121 67 Not existed

Page 1287 of 5121

TRUNK LID OPENER SWITCH
DLK-71
< COMPONENT DIAGNOSIS >[WITH INTELLIGENT KEY SYSTEM]
C
D
E
F
G
H
I
J
L
MA
B
DLK
N
O
P
NO >> Repair or replace harness.
3.CHECK TRUNK LID OPENER SWITCH GROUND CIRCUIT
Check continuity between trunk lid opener switch harness connector and ground.
Is the inspection result normal?
YES >> GO TO 4.
NO >> Repair or replace harness.
4.CHECK TRUNK LID OPENER SWITCH
Refer to DLK-71, "
Component Inspection".
Is the inspection result normal?
YES >> GO TO 5.
NO >> Replace trunk lid opener switch. Refer to DLK-243, "
Removal and Installation".
5.CHECK INTERMITTENT INCIDENT
Refer to GI-35, "
Intermittent Incident".
>> INSPECTION END
Component InspectionINFOID:0000000003794873
1.CHECK TRUNK LID OPENER SWITCH
1. Turn ignition switch OFF.
2. Disconnect trunk lid opener switch connector.
3. Check continuity between trunk lid opener switch terminal.
Is the inspection result normal?
YES >> INSPECTION END
NO >> Replace trunk lid opener switch. Refer to DLK-243, "
Removal and Installation".
Trunk lid opener switch
GroundContinuity
Connector Terminal
M25 2 Existed
Trunk lid opener switch
Condition Continuity
Te r m i n a l
12ON (press and hold) Existed
OFF (release) Not existed

Page 1288 of 5121

DLK-72
< COMPONENT DIAGNOSIS >[WITH INTELLIGENT KEY SYSTEM]
DOOR REQUEST SWITCH
DOOR REQUEST SWITCH
DescriptionINFOID:0000000003794874
Transmits lock/unlock operation to BCM.
Component Function CheckINFOID:0000000003794875
1.CHECK FUNCTION
Check door request switch (“REQ SW-DR” or “REQ SW-AS”) in Data Monitor mode.
Is the inspection result normal?
YES >> Door request switch is OK.
NO >> Refer to DLK-72, "
Diagnosis Procedure".
Diagnosis ProcedureINFOID:0000000003794876
1.CHECK BCM OUTPUT SIGNAL
1. Turn ignition switch OFF.
2. Disconnect malfunctioning front outside handle (request switch) connector.
3. Check signal between malfunctioning front outside handle (request switch) harness connector and ground
with oscilloscope.
Is the inspection result normal?
YES >> GO TO 3.
NO >> GO TO 2.
2.CHECK DOOR REQUEST SWITCH CIRCUIT
1. Disconnect BCM connector.
2. Check continuity between BCM harness connector and malfunctioning front outside handle (request
switch) harness connector.
3. Check continuity between BCM harness connector and ground.
Monitor item Condition
DR REQ SW
AS REQ SWDoor request switch is pressed: ON
Door request switch is released: OFF
(+)
(–)Signal
(Reference value) Front outside handle (request switch)
Connector Terminal
LH D11
1 Ground
RH D50
JMKIA0059GB
BCM Front outside handle (request switch)
Continuity
Connector Terminal Connector Terminal
M122101 LH D11
1 Existed
100 RH D50

Page 1289 of 5121

DOOR REQUEST SWITCH
DLK-73
< COMPONENT DIAGNOSIS >[WITH INTELLIGENT KEY SYSTEM]
C
D
E
F
G
H
I
J
L
MA
B
DLK
N
O
P
Is the inspection result normal?
YES >> Replace BCM. Refer to BCS-78, "Removal and Installation".
NO >> Repair or replace harness.
3.CHECK DOOR REQUEST SWITCH GROUND CIRCUIT
Check continuity between malfunctioning front outside handle (request switch) harness connector and ground.
Is the inspection result normal?
YES >> GO TO 4.
NO >> Repair or replace harness.
4.CHECK DOOR REQUEST SWITCH
Refer to DLK-73, "
Component Inspection".
Is the inspection result normal?
YES >> GO TO 5.
NO >> Replace malfunctioning front outside handle. Refer to DLK-224, "
OUTSIDE HANDLE : Removal
and Installation".
5.CHECK INTERMITTENT INCIDENT
Refer to GI-35, "
Intermittent Incident".
>> INSPECTION END
Component InspectionINFOID:0000000003794877
1.CHECK DOOR REQUEST SWITCH
1. Turn ignition switch OFF.
2. Disconnect front outside handle (request switch) connector.
3. Check front outside handle (request switch).
Is the inspection result normal?
YES >> INSPECTION END
NO >> Replace front outside handle. Refer to DLK-224, "
OUTSIDE HANDLE : Removal and Installation".
BCM
GroundContinuity
Connector Terminal
M122101
Not existed
100
Front outside handle (request switch)
GroundContinuity
Connector Terminal
LH D11
2Existed
RH D50
Front outside handle (request switch)
Door request switch condition Continuity
Te r m i n a l
12Pressed Existed
Released Not existed

Page 1290 of 5121

DLK-74
< COMPONENT DIAGNOSIS >[WITH INTELLIGENT KEY SYSTEM]
TRUNK LID OPENER REQUEST SWITCH
TRUNK LID OPENER REQUEST SWITCH
DescriptionINFOID:0000000003794878
Performs trunk lid open request when it is pressed.
Component Function CheckINFOID:0000000003794879
1.CHECK FUNCTION
Check trunk lid opener request switch (“REQ SW -BD/TR ”) in Data Monitor mode.
Is the inspection result normal?
YES >> Trunk lid opener request switch is OK.
NO >> Refer to DLK-74, "
Diagnosis Procedure".
Diagnosis ProcedureINFOID:0000000003794880
1.CHECK TRUNK LID OPENER SWITCH OUTPUT SIGNAL
1. Turn ignition switch OFF.
2. Disconnect trunk lid opener request switch connector.
3. Check signal between trunk lid opener request switch harness connector and ground with oscilloscope.
Is the inspection result normal?
YES >> GO TO 3.
NO >> GO TO 2.
2.CHECK TRUNK LID OPENER REQUEST SWITCH CIRCUIT
1. Disconnect BCM connector.
2. Check continuity between BCM harness connector and trunk lid opener request switch harness connec-
tor.
3. Check continuity between BCM harness connector and ground.
Is the inspection result normal?
Monitor item Condition
REQ SW -BD/TR Trunk lid opener request switch is pressed: ON
Trunk lid opener request switch is released: OFF
(+)
(–)Signal
(Reference value) Trunk lid opener request switch
Connector Terminal
T6 1 Ground
JPMIA0016GB
BCM Trunk lid opener request switch
Continuity
Connector Terminal Connector Terminal
M121 61 T6 1 Existed
BCM
GroundContinuity
Connector Terminal
M121 61 Not existed

Page:   < prev 1-10 ... 1241-1250 1251-1260 1261-1270 1271-1280 1281-1290 1291-1300 1301-1310 1311-1320 1321-1330 ... 5130 next >