check engine INFINITI QX4 2001 Factory Service Manual

INFINITI QX4 2001 Factory Service Manual QX4 2001 INFINITI INFINITI https://www.carmanualsonline.info/img/42/57027/w960_57027-0.png INFINITI QX4 2001 Factory Service Manual

Page 1027 of 2395

INFINITI QX4 2001  Factory Service Manual If the check result is OK, perform the following step.
4) Let engine idle at least 5 minutes.
5) Maintain the following condition at least 50 consecutive sec-
onds.
B/FUEL SCHDL 3.6 msec or more
ENG S

Page 1028 of 2395

INFINITI QX4 2001  Factory Service Manual SEF999Y
Component DescriptionNBEC0532The swirl control valve control vacuum check switch detects
vacuum signal to the swirl control valve, and sends ªONº or ªOFFº
signal to the ECM.
When vacuum is

Page 1029 of 2395

INFINITI QX4 2001  Factory Service Manual On Board Diagnosis LogicNBEC0535Malfunction is detected when the swirl control valve control vacuum
check switch remains ªOFFº under specified engine conditions.
Possible CauseNBEC0536IHarness or co

Page 1031 of 2395

INFINITI QX4 2001  Factory Service Manual Diagnostic ProcedureNBEC0539
1 CHECK HOSES
1. Turn ignition switch ªOFFº.
2. Check hose for clogging or improper connection.
SEF109L
OK or NG
OK©GO TO 2.
NG©Repair or reconnect the hose.
2 CHECK S

Page 1033 of 2395

INFINITI QX4 2001  Factory Service Manual 6 CHECK SWIRL CONTROL VALVE CONTROL SOLENOID VALVE
With CONSULT-II
1. Reconnect the disconnected harness connectors.
2. Start engine and let it idle.
3. Remove vacuum hose connected to swirl control v

Page 1039 of 2395

INFINITI QX4 2001  Factory Service Manual Diagnostic ProcedureNBEC0291
1 CHECK ENGINE START
Turn ignition switch ªOFFº, and restart engine.
Is engine running?
YesorNo
Yes (With CONSULT-II)©GO TO 2.
Yes (Without CONSULT-
II)©GO TO 12.
No©

Page 1042 of 2395

INFINITI QX4 2001  Factory Service Manual 10 CHECK CONDENSER GROUND CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch OFF.
2. Check harness continuity between condenser terminal 2 and engine ground. Refer to Wiring Diagram.
Continuity should

Page 1043 of 2395

INFINITI QX4 2001  Factory Service Manual 12 CHECK IGNITION COIL POWER SUPPLY CIRCUIT-V
1. Turn ignition switch OFF.
2. Reconnect harness connectors disconnected.
3. Disconnect ignition coil harness connector.
SEF975Y
4. Turn ignition switch

Page 1049 of 2395

INFINITI QX4 2001  Factory Service Manual Diagnostic ProcedureNBEC0580
1 RETIGHTEN GROUND SCREWS
1. Turn ignition switch ªOFFº.
2. Loosen and retighten engine ground screws.
SEF959Y
©GO TO 2.
2 CHECK CKPS (REF) INPUT SIGNAL CIRCUIT FOR OPE

Page 1050 of 2395

INFINITI QX4 2001  Factory Service Manual 4 CHECK CKPS (REF) GROUND CIRCUIT FOR OPEN AND SHORT
1. Turn ignition switch ªOFFº.
2. Check harness continuity between CKPS (REF) terminal 1 and engine ground.
Continuity should exist.
3. Also chec