AUTOMATIC TRANSMISSION
Fault finding - Interpretation of parameters23A
23A - 111V5 MR-372-J84-23A100$696.mif
SIEMENS TA2005
Vdiag No.: 14-18
PR004
GEARBOX OIL TEMPERATURE
NOTESThere must be no present or stored faults.
Gearbox oil temperature values vary according to how the vehicle is used.
Check the oil temperature values on the diagnostic tool:
Minimum temperature: - 40 ˚C.
Maximum temperature: + 140 ˚C.
These values relate to normal operation of the vehicle.
AFTER REPAIRRepeat the conformity check from the start.
DP0TA2005_V14_PR004/DP0TA2005_V18_PR004
Page 112 of 139

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of parameters23A
23A - 112V5 MR-372-J84-23A100$696.mif
SIEMENS TA2005
Vdiag No.: 14-18
PR006
ENGINE SPEED
NOTESThere must be no present or stored faults.
Run a multiplex network test (see 88B, Multiplex).
After these checks, if parameter PR006 Engine speed is absent, refer to the interpretation of the parameter
(see 17B, Petrol injection or 13B, Diesel injection).
AFTER REPAIRRepeat the conformity check from the start.
DP0TA2005_V14_PR006/DP0TA2005_V18_PR006
Page 113 of 139

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of parameters23A
23A - 113V5 MR-372-J84-23A100$696.mif
SIEMENS TA2005
Vdiag No.: 14-18
PR007
TURBINE SPEED
NOTESThere must be no present or stored faults.
Turbine speed varies according to oil temperature and pressure.
Turbine speed depends on engine speed.
Check the turbine speed on the diagnostic tool:
Gear lever in position N.
Oil temperature 43 ˚C: engine speed ~ 762 rpmturbine speed ~ 681 rpm.
Oil temperature 45 ˚C: engine speed ~ 743 rpmturbine speed ~ 654 rpm.
AFTER REPAIRRepeat the conformity check from the start.
DP0TA2005_V14_PR007/DP0TA2005_V18_PR007
Page 114 of 139

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of parameters23A
23A - 114V5 MR-372-J84-23A100$696.mif
SIEMENS TA2005
Vdiag No.: 14-18
PR008
COMPUTER SUPPLY VOLTAGE
NOTESThere must be no present or stored faults.
All electrical consumers switched off.
Carry out a full battery and charging circuit check (see Technical Note 6014A, Charging circuit fault finding).
Disconnect the computer.
Check the cleanliness and condition of the connector.
Check for earth on connection N of component 119.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check the computer's 30A fuse.
Check the computer's 5A after ignition feed fuse.
With the ignition on, check for + 12 V on the following connections:
●connection code BP42, between components 119 and 1337,
●connection code AP4, between components 119 and 1337.
If any of the connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring
repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check for earth on the following connections:
●connection code N of component 119,
●connection code M of component 119.
Check the Protection and Switching Unit if necessary.
AFTER REPAIRRepeat the conformity check from the start.
DP0TA2005_V14_PR008/DP0TA2005_V18_PR008
Page 115 of 139

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of parameters23A
23A - 115V5 MR-372-J84-23A100$696.mif
SIEMENS TA2005
Vdiag No.: 14-18
PR105
VEHICLE SPEED
NOTESThere must be no present or stored faults.
Run a multiplex network test (88B, Multiplex).
If parameter PR105 Vehicle speed is absent, carry out fault finding on the system (see 38C, ABS).
AFTER REPAIRRepeat the conformity check from the start.
DP0TA2005_V14_PR105/DP0TA2005_V18_PR105
Page 116 of 139

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of parameters23A
23A - 116V5 MR-372-J84-23A100$696.mif
SIEMENS TA2005
Vdiag No.: 14-18
PR118
GEARBOX OIL PRESSURE SENSOR VOLTAGE
NOTESNo faults should be present or stored.
ELECTRICAL CONFORMITY OF THE SENSOR:
Check for continuity and absence of interference resistance on the following connections:
●connection code 5U, between components 119 and 781,
●connection code 5W, between components 119 and 781,
●connection code 5V, between components 119 and 781.
If any of the connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring
repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If all the connections are correct, check for + 5 V on connection 5U of component 781.
If the connection is faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring repair,
Wiring: Precautions for repair), repair the wiring, otherwise replace it.
If all the connections are correct, check for earth on connection 5V of component 781.
If any of the connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring
repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
AFTER REPAIRRepeat the conformity check from the start.
DP0TA2005_V14_PR118/DP0TA2005_V18_PR118
Page 117 of 139

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of parameters23A
23A - 117V5 MR-372-J84-23A100$696.mif
SIEMENS TA2005
Vdiag No.: 14-18
PR123
CALCULATED ENGINE TORQUE
NOTESThere must be no present or stored faults.
Run a multiplex network test (see 88B, Multiplex).
If parameter PR123 Calculated engine torque is absent, refer to the interpretation of the parameter (see 17B,
Petrol injection or 13B, Diesel injection).
AFTER REPAIRRepeat the conformity check from the start.
DP0TA2005_V14_PR123/DP0TA2005_V18_PR123
Page 118 of 139

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of parameters23A
23A - 118V5 MR-372-J84-23A100$696.mif
SIEMENS TA2005
Vdiag No.: 14-18
PR124
ACCELERATOR PEDAL POSITION FOR DOWNSHIFTING
NOTESThere must be no present or stored faults.
Run a multiplex network test (see 88B, Multiplex).
If parameter PR124 Accel. pedal position for downshifting is absent, consult the interpretation of the parameter
(see 17B, Petrol injection or 13B, Diesel injection).
AFTER REPAIRRepeat the conformity check from the start.
DP0TA2005_V14_PR124/DP0TA2005_V18_PR124
Page 119 of 139

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of parameters23A
23A - 119V5 MR-372-J84-23A100$696.mif
SIEMENS TA2005
Vdiag No.: 14-18
PR126
CURRENT TURBINE SPEED
NOTESThere must be no present or stored faults.
Check the cleanliness and condition of the turbine speed sensor and its connections.
Check the insulation, continuity and the absence of interference resistance to earth, to + 12 V and the
following connections:
●connection code 5DA, between components 119 and 1017,
●connection code 5DB, between components 119 and 1017.
If any of the connections are faulty and there is a repair procedure (see Technical Note 6015A, Electrical wiring
repair, Wiring: Precautions for repair), repair the wiring, otherwise replace it.
Check the turbine speed on the diagnostic tool:
Gear lever position at N or P.
Oil temperature 43 ˚C: turbine speed ~ 681 rpm and engine speed: ~ 743 rpm.
Oil temperature 45 ˚C: turbine speed ~ 654 rpm and engine speed: ~ 743 rpm.
AFTER REPAIRRepeat the conformity check from the start.
DP0TA2005_V14_PR126/DP0TA2005_V18_PR126
Page 120 of 139

AUTOMATIC TRANSMISSION
Fault finding - Interpretation of parameters23A
23A - 120V5 MR-372-J84-23A100$696.mif
SIEMENS TA2005
Vdiag No.: 14-18
PR128
ENGINE/TURBINE SPEED DIFFERENCE
NOTESThere must be no present or stored faults.
Check the cleanliness and condition of the engine speed sensor and its connections.
Run a multiplex network test (see 88B, Multiplex).
After these checks, if parameter PR006 Engine speed is absent, refer to the interpretation of the parameter
(see 17B, Petrol injection or 13B, Diesel injection).
Check the cleanliness and condition of the turbine speed sensor and its connections.
This parameter is the difference between parameter PR006 Engine speed and parameter PR007 Turbine speed.
Check the engine/turbine speed difference with the diagnostic tool:
Engine idling:
Engine speed: ~ 743 rpm and turbine speed: ~ 654 rpmdifference = ~ 89 rpm.
AFTER REPAIRRepeat the conformity check from the start.
DP0TA2005_V14_PR128/DP0TA2005_V18_PR128