LEXUS LS430 2003 Factory Repair Manual
Page 201 of 4500
a. Disconnect the skid control ECU connector.  
b. Measure the resistance according to the value (s) in the table below. 
Standard:  
TESTER CONNECTION SPECIFIED CONDITION 
c. Measure the resistance according to the value (s) in the table below.  
Standard:  
TESTER CONNECTION SPECIFIED CONDITION 
NG: REPAIR OR REPLACE HARNESS OR CONNECTOR
Tester ConnectionSpecified Condition
S42-24 (TS) - D1-12 (TS)Below 1 ohms
Tester ConnectionSpecified Condition
S42-24 (TS) - Body ground1 Mohms or higher 
Page 202 of 4500
Fig. 142: Identifying Skid Control ECU Terminals 
Courtesy of TOYOTA MOTOR SALES, U.S.A., INC. 
OK: REPLACE ABS & TRACTION ACTUATOR ASSY (SEE REPLACEMENT
 ) 
Page 203 of 4500
Page 204 of 4500
FRONT POWER SEAT CONTROL SYSTEM REFERENCE 
1.RESTRICTION OF STEP MOTORS CONTINUOUS OPERATION 
If the step motor is continuously operating for many hours, the step motor is forced to stop and the 
"AUTO" indicator blinks. In this case, the step motor automatically restores after cooling for 
approximately 7 minutes. 
Fig. 1: Identifying Auto Indicator (W/O Lexus Navigation System)
 
Courtesy of TOYOTA MOTOR SALES, U.S.A., INC.
System NameSee Procedure
Front Power Seat Control SystemINITIALIZATION 
Page 205 of 4500
Fig. 2: Identifying Auto Indicator (W/ Lexus Navigation System) 
Courtesy of TOYOTA MOTOR SALES, U.S.A., INC.  
Page 206 of 4500
Fig. 3: Identifying Air Conditioning System Component Location (1 Of 2) 
Courtesy of TOYOTA MOTOR SALES, U.S.A., INC. 
Page 207 of 4500
Fig. 4: Identifying Air Conditioning System Component Location (2 Of 2) 
Courtesy of TOYOTA MOTOR SALES, U.S.A., INC. 
Page 208 of 4500
Fig. 5: Air Conditioning System Diagram (1 Of 2) 
Courtesy of TOYOTA MOTOR SALES, U.S.A., INC. 
Page 209 of 4500
Page 210 of 4500
Fig. 6: Air Conditioning System Diagram (2 Of 2)
Courtesy of TOYOTA MOTOR SALES, U.S.A., INC. 
1.GENERAL 
a. The air conditioning system has the following features: 
In compliance with the temperature set at the temperature control switch, the neural network 
control calculates the outlet temperature based on the input signals from various sensors. In 
addition, corrections in accordance with the signals from the evaporative temperature sensor 
and the water temperature sensor are added to control the outlet air temperature.  
Controls the front and rear blower motors in accordance with the airflow volume that has 
been calculated by the neural network control based on the input signals from various 
sensors.  
Automatically switches the outlets in accordance with the outlet mode ratio that has been 
calculated by the neural network control based on the input signals from various sensors.  
Automatically controls the air inlet control damper in accordance with the airflow volume 
that has been calculated by the neural network control.  
Turns the compressor on/off and controls the discharge capacity based on the signals from 
various sensors.  
Based on the signals from the ambient temperature sensor, this control calculates the outside 
temperature, which is then corrected in the air conditioner ECU, and shown in the multi-
information display in the combination meter.  
Switched the rear defogger and outside rear view mirror heaters on for 15 minutes when the 
rear defogger switch is switched on. Switched them off if the switch is pressed while they are 
operating.  
Controls the orientation and the angle of the front center register based on the input signals 
from various sensors and on the outlet mode.  
Determines whether the clean air filter (for the front A/C) is clogged by monitoring the air 
inlets, and airflow volume.  
The A/C amplifier automatically controls the air inlets based on the signals from the smog 
ventilation sensor.  
Improves the air quality by linking the air inlet control damper and the blower motor (for the 
rear A/C and air purifier), based on the signals from the exhaust gas sensor and the smoke 
sensor.  
Checks the sensors in accordance with operation of the air conditioner switches.  
2.MODEL POSITION AND DAMPER OPERATION