174Section 2 Malfunction Symptom Table and Solution ProcedureI.MALFUNCTION SYMPTOM TABLEThe table below lists the typical malfunction symptoms of the combination meter. These malfunctions can be
solved by the procedure in the section of the Malfunction Diagnosis.Serial No. MALFUNCTION SYMPTOM
1 The whole c ombination me te r does not ope ra te
2 Spe e dome ter ma lfunction
3 Tac home te r malfunc tion
4 Water temperature gauge malfunction
5 Fue l ga uge malfunc tion
6 O dome te r ma lfunc tion
175II. DETAILED SOLUTION PROCEDURE1. THE WHOLE COMBINATION METER
DOSE NOT OPERATE.
(a) Inspect fuse
1Check fuse CLUSTER (10A) in the main fuse
box for continuity.
2Check fuse AM (30A) in the main fuse box
for continuity.
3Check fuse MAIN (80A) in the fuse box for
continuity.
Result and solution: If a certain fuse is burnt, replace a fuse
with the same capacity.Ignition SwitchMain Fuse BoxCombined Meter AssemblyBatteryFuse Box