Page  51   of  89   Report No. :  60404488 001  
 
IEC 62368 - 1  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
  9.6   TABLE: Temperature measurements for wireless power transmitters  
N/A  
Supply voltage (V)   ................................ .......... :    
  
Max. transmit power of transmitter (W)   .......... :    
  
Foreign objects   w/o receiver and 
direct contact   w ith receiver and 
direct contact   with receiver and at 
distance of 2 mm   with receiver and at 
distance of 5 mm  
  Object 
( o
C)   Ambient 
( o
C)   Object 
( o
C)   Ambient 
( o
C)   Object 
( o
C)   Ambient 
( o
C)   Object 
( o
C)   Ambient 
( o
C)  
                 
Supplementary information:  
 
 
 
 
5.4 .1.4 ,   
9.3,  B.1.5 , 
B.2.6   TABLE: Temperature measurements  
P  
Supply voltage (V)   ................................ ..........   :   14.4 V 
d.c.   14.4 V 
d.c.   14.4 V 
d.c.    
  
Ambient temperature during test  T
amb  (  C)   ....   :   22.6   25  1)
  85   2)
   
  
Maximum measured temperature  T   of part/at:  
T   (  C)   Allowed 
T
max   (  C)  
1 . Display PCB near IC100   46.8   -   109.2     130  
2. Display panel body (Not accessible)   48.4   -   110.8     -  
3. Connector body (CN310)   47.1   -   109.5     -  
4. PCB near SD card slot   36.9   -   99.3     130  
5. Main PCB near CN150   45.6   -   108.0     130  
6. Main PCB near IC 402   64.3   -   126.7     130  
7. Main PCB near L304   53.7   -   116.1     130  
8. Main to Display connector body (CN951)   56.0   -   118.4     -  
9. PCB near BD7820   24.9   -   87.3     130  
10. PCB near CN151   46.8   -   109.2     130  
11. Amp IC body (IC163)   62.6   -   125.0     -  
12. PCB near C298   57.0   -   119.4     130  
13. Main to Antenna connector body (CN990)   58.0   -   120.4     -  
14. Antenna PCB near IC182   61.4   -   123.8     130  
15. Monitor body   38.9   41.3   -     71   
Page 162 of 406

   
 
Page  52   of  89   Report No. :  60404488 001  
 
IEC 62368 - 1  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
  16. Power key knob body   26.6   29.0   -     60  
17. Enclosure near media button   29.9   32.3   -     77  
18. Frame body   (Not accessible)   33.8   -   96.2     -  
19. Metal enclosure body (Not accessible)   42.5   -   104.9     -  
Ambient temperature   See 
above   See 
above   See 
above     -  
Temperature T of winding:   t
1   (°C)  
R
1   (  )   t
2   (°C)  
R
2   (  )   T (  C)   Allowed 
T
max   (  C)   Insulation 
class  
               
S upplementary information:  
Note 1. The temperatures for accessible parts are adjusted to reflect a value of 25 °C .  
Note 2. Maximum operating Temperature pe rmitted by the Manufacturer(Tma) is  85    C .  
 
 
 
B.2.5   TABLE: Input test  
P  
U (V)   Hz   I (A)   I rated (A)   P   (W)   P rated (W)   Fuse No   I fuse (A)   Condition/status  
10.2   -   2.04   -   20.81   -   -   -  
Max. normal 
load condition.  
12.0   -   1.92   3.5   23.04   -   -   -  
Max. normal 
load condition.  
14.4   -   1.89   -   27.22   -   -   -  
Max. normal 
load condition.  
Supplementary information:  
Max. nor mal load condition :  The  equipment   is operated in such a way as to deliver one - eighth of the NON -
CLIPPED   OUTPUT POWER to the RATED LOAD IMPEDANCE ( 4Ω )   using the standard signal described 
in  Annex E and  Max. brightness for LCD module.  
 
  
Page 163 of 406

   
 
Page  53   of  89   Report No. :  60404488 001  
 
IEC 62368 - 1  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
  
B.3, B.4   TABLE: Ab normal operating and fault condition tests  
P  
Ambient temperature T
amb   (  C)   ................................ .....................   :   2 1 - 2 3  
  
Power source for EUT: Manufacturer, model/type, outputrating   ..   :   -  
  
Component No.   Condition   Supply 
voltage 
(V)   Test 
time   Fuse no.   Fuse 
current 
(A)   Observation  
Ventilati on 
openings   Block ed   14.4   2   h   -   -   FI  :  1.89   A, NO,   
CT (Monitor  body   : 3 8. 1    C,  
Power key knob body   :  2 6. 9  
 C,  Enclosure near media 
button   : 29. 9    C,   Ambient : 
2 2 .6    C, NCD, NH  
Speaker output   Max. non -
clipped output   14.4   2   h   -   -   FI  :  3.14   A, NO,   
CT ( Amp I C body (IC163) : 
64.8    C ,   Monitor  body   : 3 8. 1  
 C,   Power key knob body   : 
26. 7    C,  Enclosure near 
media button   : 29. 6    C,  
Ambient : 2 2.4    C, NCD, NH  
Speaker output   SC   14.4   1   h   -   -   FI  :  0.5  -   1. 27   A ,  IP , NCD, 
NH  
IC101(3,8)   SC   14.4   1   h   -   -   FI   :  0.5 A ,  CD(IC1 01) , NH  
IC902(1,6)   SC   14.4   1   h   -   -   FI  :  0.5 A ,  CD(IC902) , NH  
Supplementary information:  
Abbreviation:   
FI  –   Final Input Current; IP  –   Internal protection operated;   NO  –   Normal Operated;  
CD  –   Component Damaged (list damaged components); NCD  –   No Component   Damaged;  
NH  –   No Hazard ;  CT  –   Constant temperatures were obtained (list components: temperature;);  
NB  –   No indication of dielectric breakdown; YB  –   Dielectric breakdown (indicate time and location);  
NC  –   Cheesecloth remained intact; YC  –   Cheesecloth char red or flamed;  
  
Page 164 of 406

   
 
Page  54   of  89   Report No. :  60404488 001  
 
IEC 62368 - 1  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
  
M.3   TABLE: Protection circuits for batteries provided within the equipment  
N/A  
Is it possible to install the battery in a reverse polarity position? ......   :    
  
Equipment Specification   Charging  
Voltage (V)   Current (A)  
   
Manufacturer/type   Battery specification  
Non - rechargeable batteries   Rechargeable batteries  
Discharging 
current (A)   Unintentional 
charging 
current (A)   Charging   Discharging 
current (A)   Reverse 
charging 
current (A)  Voltage (V)   Current (A)  
             
Note: The tests of  M.3.2 are applicable only when above appropriate data is not available.   
Specified battery temperature ( o
C)   ................................ ...................   :      
Componen
t No.   Fault 
condition   Charge/ 
discharge mode   Test 
time   Temp. 
( o
C)   Current 
(A)   Voltage 
(V)   Observation  
               
Supplementary informat ion:  
Abbreviation: SC= short circuit; OC= open circuit NL= no chemical leakage; NS= no spillage of liquid; NE= 
no explosion; NF= no emission of flame or expulsion of molten metal.  
 
 
M.4.2   TABLE:  Charging  safeguards  for  equipment  containing  a  secondary  lit hium 
battery   N/A  
Maximum specified charging voltage (V)   ................................ .....   :    
  
Maximum specified charging current (A)    ................................ .....   :    
  
Highest specified charging temperature ( o
C)    ..............................   :      
Lowest specified charging temperature ( o
C)    ...............................   :      
Battery 
manufacturer/type   Operating 
and fault 
co ndition   Measurement   Observation  
Charging 
voltage (V)   Charging 
current (A)   Temp.   
( o
C)    
           
Supplementary information:  
Abbreviation: SC= short circuit; OC= open circuit; MSCV= maximum specified charging voltage; MSCC= 
maximum specified charging curre nt; HSCT= highest specified charging temperature; LSCT= lowest 
specified charging temperature   
Page 165 of 406

   
 
Page  55   of  89   Report No. :  60404488 001  
 
IEC 62368 - 1  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
  
Q.1   TABLE: Circuits intended for interconnection with building wiring (LPS)  
N/A  
Output 
Circuit   Condition   U
oc   (V)   Time (s)   I
sc  (A)   S (VA)  
Meas.   Limit   Meas.   Limit  
   
   
   
   
   
   
   
   
Supplementary Information:  
SC=Short circuit, OC=Open circuit  
 
 
T.2, T.3, 
T.4, T.5   TABLE: Steady force test  
N/A  
Part/Location   Material   Thickness 
(mm)   Probe   Force  
(N)   Test 
Duration  
(s)   Observation  
             
Supplementary informat ion:  
 
 
T.6, T.9   TABLE: Impact test  
P  
Location/part   Material   Thickness 
(mm)   Height 
(mm)   Observation  
Front, Top / Monitor   PC /ABS   Min. 1.5   1 300   No damaged, no hazard  
Front / Keyboard   PC/ABS   Min. 1.5   1 300   No damaged, no hazard  
Supplementary information:  
 
 
T.7     TABLE: Drop test  
N/A  
Location/part   Material   Thickness 
(mm)   Height 
(mm)   Observation  
         
Supplementary information:  
 
  
Page 166 of 406

   
 
Page  56   of  89   Report No. :  60404488 001  
 
IEC 62368 - 1  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
  
T.8   TABLE: Stress relief test  
P  
Location /Part   Material   Thickness 
(mm)   Oven Temperature 
(  C)   Duration  
(h)   Observation  
Monit or , Keyboard   PC /ABS   Min. 1.5   102. 3   7   No shrinkage or 
distortion.  
No defeat its 
safeguard function.  
Supplementary information:  
 
 
X   TABLE: Alternative method for determining minimum clearances distances  
N/A  
Clearance distanced 
between:   Peak of working vol tage 
(V)   Required cl  
(mm)   Measured cl  
(mm)  
       
Supplementary information:  
 
 
  
Page 167 of 406

   
 
Page  57   of  89   Report No. :  60404488 001  
 
IEC 62368 - 1  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
  
4.1.2   TABLE: Critical components information  
P  
Object / part No.   Manufacturer/  
trademark   Type / model   Technical data   Standard   Mark(s) of 
conformity 1)
 
Plastic 
Enclosure   LG C HEM LTD   LUPOY GN -
5007F(#)   V - 0   UL 94   UL   ( E67171 )  
Alternate   Interchangeable   Interchangeable   Min.  HB   UL 94   UL  
-   Description:   Interchangeability based on specified ratings  
Metal Enclosure   Interchangeable   Interchangeable   AL or EGI(SECC)  
or GI(SGCC) or   
NI or   ALDC or   
MG or SUS or   
STS or NSP or   
STEEL, Min. 0.4   
thickness   IEC 62368 - 1   Tested in 
equipment    
-   Description:   Interchangeability based on specified ratings and dimensions  
PCB   ZHEJIANG 
HUABANG 
ELECTRONICS 
CO LTD   H - 01   V - 0   UL 796   UL   ( E251053 )  
Alternate   HYUN WOO 
INDUSTRIAL 
CO LTD   3   V - 0   UL 796   UL (E131308)  
Alternate    Interchangeable   Interchangeable   Min. V - 1   UL 796   UL  
-   Description:   Interchangeability based on specified ratings  
LCD Panel   LG Display   Co., 
Ltd.   LA065WV1   6.5 inch ,    
( 800   x   480  )   IEC 62368 - 1   Tested in 
equipment    
Alternate   LG Display 
(Paju) Co., Ltd.   LA065WV3   6.5 inch ,    
( 800   x   480  )   IEC 60065   T Ü V - Rh  
(JPTUV -
080511)  
Alternate   Giantplus 
Technology Co., 
LTD.   GPM1696A0   6.5 inch ,    
( 800   x   480  )   IEC 60065   SGS F imko  
(FI - 37636)  
Mains connector 
materia l   KURARAY CO 
LTD   GN2330(#)   V - 0   UL 94   UL (E90350)  
Alternate   Interchangeable   Interchangeable   Min. V - 1   UL   94   UL  
-   Description:   Interchangeability based on specified ratings  
Fuse   ST   VN5E 010MHTR -
E   13A Switch off   ISO/TS 
16949:2009   9136.STM2  
Supplementary information:  
1) 
Provided evidence ensures the agreed level of compliance. See OD - 2039.   
Page 168 of 406

   
 
Page  58   of  89   Report No. :  60404488 001  
 
IEC 62368 - 1  –   ATTACHMENT 1  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
TRF No.  IEC62368_1 C    ATTACHMENT TO TEST R EPORT  
IEC 62368 - 1  
EUROPEAN GROUP DIFFE RENCES AND NATIONAL  DIFFERENCES  
(AUDIO/VI DEO, INFORMATION AND   COMMUNICATION TECHN OLOGY EQUIPMENT  -   PA RT 1: SAFETY 
REQUIREMENTS)  
Differences  according to   ................   :  
EN 62368 - 1:2014+A11:2017  
Attachment Form No .   .....................   :  
EU_GD_IEC62368_1B_II  
Attachment Originator   ...................   :  
Nemko AS  
Master Attachment   .........................   :  
Date 2017 - 09 - 22  
Copyright ©  2017 IEC System for Conformity Testing and Certification of Electrical Equipment (IECEE), 
Geneva, Switzerland. All rights reserved.  
  CENELEC COMMON MODIFICATIONS (EN)  
P  
  Clauses, subclauses, notes, tables, figures and annexes which are additi onal to those in 
IEC 62368 - 1:2014 are prefixed “Z”.   P  
CONTENTS   Add   the following annexes:  
Annex ZA (normative)     Normative references to international publications   
                               with their corresponding European publications  
Annex ZB (normati ve)     Special national conditions  
Annex ZC (informative)     A - deviations  
Annex ZD (informative)     IEC and CENELEC code designations for flexible   
                         cords         P  
  Delete   all the “country” notes in the reference document (IEC 62368 - 1:2014) accor ding 
to the following list:  
  P   
Page 169 of 406

   
 
Page  59   of  89   Report No. :  60404488 001  
 
IEC 62368 - 1  –   ATTACHMENT 1  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
  
  For special national conditions, see Annex ZB.  
1   Add   the following note:  
NOTE Z1  The use of certain substances in electrical and electronic 
equipment is restricted within the EU: see Directive 2011/65/EU.     P  
4.Z1   Add   the following new subclause after 4.9:  
To protect against excessive current, short - circuits and 
earth faults in circuits connected to an a.c.  mains , 
protective devices shall be included either as integral 
parts of the equipment or as parts of the building 
installation, subject to the following, a), b) and c):  
a) except as detailed in b) and c), protective devices 
necessary to comply with the requirements of B.3.1 and 
B.4 shall be included as parts of the equipment;  
b) for components in series with the mains   input to the 
equipment such as the supply cord, appliance coupler, 
r.f.i. filter and switch, short - circuit and earth fault 
protection may be provided by protective devices in the 
building installation;  
c) it is permitted for  pluggable equipment type B   or 
permanently connected equipment , to rely on 
dedicated overcurrent and short - circuit protection in the 
building installation, provided that the means of 
protection, e.g. fuses or circuit breakers, is fully 
specified in the installation instructions.  
If reli ance is placed on protection in the building 
installation, the installation instructions shall so state, 
except that for  pluggable equipment type A   the 
building installation shall be regarded as providing 
protection in accordance with the rating of the wal l 
socket outlet.     N/A  
5.4.2.3.2.4   Add   the following to the end of this subclause:  
The requirement for interconnection with  external 
circuit   is in addition given in EN 50491 - 3:2009.     N/A  
10.2.1   Add the following to  c)
  and  d)
  in table 39:  
For additional re quirements, see 10.5.1.     N/A   
Page 170 of 406

   
 
Page  60   of  89   Report No. :  60404488 001  
 
IEC 62368 - 1  –   ATTACHMENT 1  
Clause   Requirement + Test   Result  -   Remark   Verdict  
 
 
TR F No.  IEC62368_1 C    
 10.5.1   Add   the following after the first paragraph:  
For RS 1 compliance is checked by measurement 
under the following conditions:  
In addition to the normal operating conditions, all 
controls adjustable from the outside by hand , by any 
object such as a tool or a coin, and those internal 
adjustments or presets which are not locked in a reliable 
manner, are adjusted so as to give maximum radiation 
whilst maintaining an intelligible picture for 1 h, at the 
end of which the measurem ent is made.  
NOTE Z1  Soldered joints and paint lockings are examples of 
adequate locking.  
The dose - rate is determined by means of a  radiation 
monitor with an effective area of 10 cm², at any point 10 
cm from the outer surface of the apparatus.  
Moreover,  the measurement shall be made under fault 
conditions causing an increase of the high - voltage, 
provided an intelligible picture is maintained for 1 h, at 
the end of which the measurement is made.  
For RS1, the do se - rate shall not exceed 1 μSv/h taking 
account of the background level.  
NOTE Z2  These values appear in Directive 96/29/Euratom of 13 May 
1996.     N/A  
10.6.1   Add   the following paragraph to the end of the 
subclause:  
EN 71 - 1:2011, 4.20 and the related tests  methods and 
measurement distances apply.     N/A  
10.Z1   Add   the following new subclause after 10.6.5.  
10.Z1 Non - ionizing radiation from radio frequencies 
in the range 0 to 300 GHz  
The amount of non - ionizing radiation is regulated by 
European Council Recommend ation 1999/519/EC of 12 
July 1999 on the limitation of exposure of the general 
public to electromagnetic fields (0 Hz to 300 GHz).  
For intentional radiators, ICNIRP guidelines should be 
taken into account for Limiting Exposure to Time -
Varying Electric, Mag netic, and Electromagnetic Fields 
(up to 300 GHz). For hand - held and body - mounted 
devices, attention is drawn to EN 50360 and EN 50566     N/A  
G.7.1   Add   the following note:  
NOTE Z1  The harmonized code designations corresponding to the 
IEC cord types are giv en in Annex ZD.     P